42mpa Wireless Differential Pressure Transmitter , 90ms Wireless Differential Pressure Sensor

Brand Name:CHONGQING CHUANYI, SICC
Certification:CE, SIL, ATEX, HART, IECEx, CSS, ISO9001, ISO14001, ISO45001
Model Number:PDS803, PDS863
Minimum Order Quantity:1 SET
Delivery Time:As Appropriate
Payment Terms:L/C, D/A, D/P, T/T
Contact Now

Add to Cart

Active Member
Location: Chongqing Chongqing China
Address: 6F,TECHNOLOGY BUILDING,CHUANYI INDUSTRIAL PARK,61 HUANGSHAN AVE,LIANGJIANG NEW AREA,CHONGQING 401121,CHINA.
Supplier`s last login times: within 40 hours
Product Details Company Profile
Product Details

Wireless Differential Pressure Transmitter


Main Technical Parameters:


Seismic Rating: Seismic Class I

Measuring Range: 0-50pa~70Mpa

Accuracy: ±0.04% (Up To ±0.025%)

Long-Term Stability: ≤±0.1%/10 Years

Fast Response: ≤ 90ms (50ms Data Refresh Time)

Range Ratio: 100:1

Explosion Protection Certification: Ex Iaiict4T6 Ga, Ex Diict6 Gb

Non-Ex NEPSI: Intrinsically Safe Ex Ia ⅡCT4 Ga

NEPSI: Intrinsically Safe Ex Ia ⅡCT6 Ga

NEPSI: Explosion-Proof Ex D ⅡCT6 Gb

NEPSI: Dust Ex Ex Td A21 IP67 T85°C

ATEX: Intrinsically Safe II 1 G Ex Ia IIC T4 Ga,

ATEX: Explosion-Proof II 1/2 G Ex Db IIC T6.... .T4 Ga/Gb

Iecex: Intrinsically Safe Ex Ia IIC T4 Ga

Iecex: Ex Db IIC T6.... .T4 Ga/Gb

NEPSI: Type "N" Ex Na ⅡC T6 Gc

Overload Limit: 42mpa

Safety Certification: SIL2

Communication Protocols: HART, Profibus-PA, FF, Wireless Hart, Zigbee

15 Local Machine Configurations And Intelligent Self-Diagnosis, Simulation And Monitoring Functions


PDS Paper Pressure Transmitter


Main Technical Parameters:


Maximum range ratio r (r = maximum range / range used) = 30:1

Long-term stability: δ≤±0.1FS%/10 years

Seismic rating: Seismic Class I

Measuring range: 0-50pa~70Mpa

Accuracy: ±0.04% (up to ±0.025%)

Long-term stability: ≤±0.1%/10 years

Fast response: ≤ 90ms (50ms data refresh time)

Range ratio: 100:1

Explosion protection certification: Ex iaIICT4T6 Ga, Ex dIICT6 Gb

Non-Ex NEPSI: Intrinsically safe Ex ia ⅡCT4 Ga

NEPSI: Intrinsically safe Ex ia ⅡCT6 Ga

NEPSI: Ex d ⅡCT6 Gb

NEPSI: Dust explosion-proof Ex tD A21 IP67 T85°C

ATEX: Intrinsically safe II 1 G Ex ia IIC T4 Ga,

ATEX: Ex II 1/2 G Ex db IIC T6.... .T4 Ga/Gb

IECEx: Intrinsically safe Ex ia IIC T4 Ga

IECEx: Ex db IIC T6.... .T4 Ga/Gb

NEPSI: Type "n" Ex nA ⅡC T6 Gc

Safety certification: SIL2


PDS Hygienic Pressure Transmitter


Main Technical Parameters:


Maximum range ratio r (r=maximum range/use range) =30:1

Long-term stability: δ≤±0.1FS%/10 years

Seismic class: Seismic class I

Measuring range: 0-50pa~70Mpa

Accuracy: ±0.04% (maximum ±0.025%)

Long-term stability: ≤±0.1%/10 years

Fast response: ≤90ms (50ms data refresh time)

Range ratio: 100:1

Ex certification: Ex iaIICT4T6 Ga, Ex dIICT6 Gb

Non-Ex NEPSI: Intrinsically safe Ex ia ⅡCT4 Ga

NEPSI: Intrinsically safe Ex ia ⅡCT6 Ga

NEPSI: Explosion-proof Ex d ⅡCT6 Gb

NEPSI: Dust explosion-proof Ex tD A21 IP67 T85°C

ATEX: Intrinsically safe II 1 G Ex ia IIC T4 Ga,

ATEX: Ex II 1/2 G Ex db IIC T6.... .T4 Ga/Gb

IECEx: Intrinsically safe Ex ia IIC T4 Ga

IECEx: Ex db IIC T6.... .T4 Ga/Gb

NEPSI: Type "n" Ex nA ⅡC T6 Gc

Safety certification: SIL2

China 42mpa Wireless Differential Pressure Transmitter , 90ms Wireless Differential Pressure Sensor supplier

42mpa Wireless Differential Pressure Transmitter , 90ms Wireless Differential Pressure Sensor

Inquiry Cart 0