Technical Parameters
Model: ZR60-1000-30U
Filter area: 60m2
Filter plate size: 1000*1000mm2
Filter cake thickness: 30mm
Single filter room volume: 908L
Filter plate quantity: 34pcs
Motor power: 4kw
Filter pressure: 0.8Mpa
Technical Parameter Of ZR Serial
Model | Filter area (M2) | Plate size (mm) | Cake thickness (mm) | Room volume (L) | Plate qty (Pcs) | Motor Power (Kw) | Filter pressure (Mpa) | Whole weight (Kg) | Outline dimension (L*W*H)(mm) | Foundation size (mm) | ||||
L | B | D | H | C | ||||||||||
ZR10-630-30U | 10 | 700*700 | 30 | 154 | 12 | 2.2 | 0.8 | 1880 | 1880*1115*1130 | 1760 | 400 | 1115 | 780 | 495 |
ZR15-630-30U | 15 | 226 | 18 | 2080 | 2950*1115*1130 | 2060 | ||||||||
ZR20-630-30U | 20 | 298 | 24 | 2280 | 3250*1115*1130 | 2360 | ||||||||
ZR25-630-30U | 25 | 375 | 31 | 2500 | 3600*1115*1130 | 2710 | ||||||||
ZR30-630-30U | 30 | 452 | 37 | 2700 | 3900*1115*1130 | 3010 | ||||||||
ZR40-630-30U | 40 | 595 | 49 | 3100 | 4500*1115*1130 | 3610 | ||||||||
ZR20-800-30U | 20 | 870*870 | 307 | 15 | 2800 | 2940*1300*1300 | 2070 | 500 | 1300 | 865 | 505 | |||
ZR30-800-30U | 30 | 460 | 23 | 3100 | 3380*1300*1300 | 2510 | ||||||||
ZR40-800-30U | 40 | 595 | 30 | 3400 | 3770*1300*1300 | 2900 | ||||||||
ZR50-800-30U | 50 | 748 | 38 | 3700 | 4210*1300*1300 | 3340 | ||||||||
ZR60-800-30U | 60 | 902 | 46 | 4100 | 4630*1300*1300 | 3760 | ||||||||
ZR70-800-30U | 70 | 1056 | 54 | 4500 | 5090*1300*1300 | 4220 | ||||||||
ZR80-800-30U | 80 | 1210 | 62 | 5000 | 5530*1300*1300 | 4660 | ||||||||
ZR50-1000-30U | 50 | 1000*1000 | 752 | 28 | 4 | 4320 | 3880*1450*1450 | 2900 | 600 | 1450 | 940 | 520 | ||
ZR60-1000-30U | 60 | 908 | 34 | 4730 | 4430*1450*1450 | 3540 | ||||||||
ZR70-1000-30U | 70 | 1063 | 40 | 5170 | 4600*1450*1450 | 3710 | ||||||||
ZR80-1000-30U | 80 | 1219 | 46 | 5580 | 4960*1450*1450 | 4070 | ||||||||
ZR100-1000-30U | 100 | 1509 | 57 | 6400 | 5890*1450*1450 | 4850 | ||||||||
ZR120-1000-30U | 120 | 1816 | 69 | 7200 | 6590*1450*1450 | 5550 | ||||||||
ZR100-1250-30U | 100 | 1250*1250 | 1519 | 36 | 5.5 | 8300 | 5040*1770*1600 | 3920 | 800 | 1770 | 980 | 435 | ||
ZR120-1250-30U | 120 | 1806 | 43 | 9000 | 5490*1770*1600 | 4370 | ||||||||
ZR140-150-30U | 140 | 2153 | 51 | 9700 | 6010*1770*1600 | 4890 | ||||||||
ZR160-1250-30U | 160 | 2422 | 58 | 10400 | 6470*1770*1600 | 5350 | ||||||||
ZR180-1250-30U | 180 | 2710 | 65 | 11100 | 6920*1770*1600 | 5800 | ||||||||
ZR200-1250-30U | 200 | 2997 | 72 | 11800 | 7380*1770*1600 | 6260 | ||||||||
ZR220-1250-30U | 220 | 3326 | 80 | 12500 | 7900*1770*1600 | 6780 | ||||||||
ZR250-1250-30U | 250 | 3778 | 91 | 14000 | 8610*1770*1600 | 7600 | ||||||||
ZR200-1500-30U | 200 | 1500*1500 | 3030 | 49 | 0.6 | 20000 | 6370*2000*1920 | 5070 | 1000 | 1970 | 1170 | 505 | ||
ZR250-1500-30U | 250 | 3739 | 61 | 22500 | 7170*2000*1920 | 5920 | ||||||||
ZR300-1500-30U | 300 | 4413 | 74 | 25000 | 8270*2000*1920 | 6880 | ||||||||
ZR350-1500-30U | 350 | 5210 | 86 | 27500 | 9110*2000*1920 | 7700 | ||||||||
ZR400-1500-30U | 400 | 6007 | 99 | 30000 | 10200*2000*1920 | 8600 | ||||||||
ZR450-1500-30U | 450 | 6743 | 111 | 33000 | 10930*2000*1920 | 9450 | ||||||||
ZR500-1500-30U | 500 | 7478 | 123 | 36500 | 11480*2000*1920 | 10580 | ||||||||
ZR600-2000-40U | 600 | 2000*2000 | 40 | 12000 | 83 | 49000 | 10615*3000*2500 | 8980 | 1200 | 2600 | 1500 | 505 | ||
ZR700-2000-40U | 700 | 14000 | 97 | 53000 | 11765*3000*2500 | 10130 | ||||||||
ZR800-2000-40U | 800 | 16000 | 111 | 57000 | 12915*3000*2500 | 11280 | ||||||||
ZR900-2000-40U | 900 | 18000 | 125 | 61000 | 14060*2000*2500 | 12425 | ||||||||
ZR1000-2000-40U | 1000 | 20000 | 139 | 65000 | 15210*2000*2500 | 13575 |
Profile
Automatic plate pulling filter press is controlled by hydraulic
system, electric control components are all adopted famous brand
products, realize manual control and full computer automatic
control.
The hydraulic device is used as the power mechanism for pressing
and loosening the filter plate, and the electric contact pressure
gauge is used to realize actions such as pressure keeping,
compression, return, and plate pulling, etc. can be achieved
automatically. Electrical parts are equipped with a variety of
safety devices to ensure the safety of operators and the normal
operation of the filter presses.
Features
Adopt low start variable frequency reducer to pull the plate
automatically, PLC program control, save time and effort, simple
operation and stable performance.
Working Principle Of Chamber Filter Press