Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To Large Data Centers

Product Introduction

CoolRow is a in-row cooling solution commonly used in data centers requring higher density cooling with greater efficiency and capacity. The unit is placed beteween the servers in a row for offering cooling close to the heat load, the horizontal airflow pattern supports hot aisles and cold aisles configeration. CoolRow improves the efficiency of the overall cooling systems and ensures the steady room temperature for precise operation.


Feature & Benefits

Energy Efficiency

Inverter compressor, EC fan and electronic expansion valve are standard configurations for DXA series

Air is directly drawn from the hot aisle, allowing the unit to take advantage of higher heat transfer efficiency due to higher Delta T.

Cold aisle/Hot ailse containment avoids mixing of cold and hot air


High Flexibility

Air-cooled or chilled water-cooled cooling scheme.

Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.

Application Range

  • Cold Aisle/Hot Aisle Application
  • Modularized Data Center Application
  • Single rack with power larger than 3kW
  • High heat density computer room
  • Modular DC
  • Container type DC
  • DC with low PUE
  • Hot spot reconstruction

Air Supply Method


Technical Parameter

ModelCRA013ACRA020ACRA040ACRA050ACRA060A
Air supplyFront/SideFront/SideFrontFrontFront
Power supply380VAC/3Ph/50Hz
Cooling capacity-KW13.226.742.653.363.9
Sensible cooling-KW13.226.742.653.363.9
Compressor
RefrigerantR410A
Quantity1
Fan
Fan typeEC Centrifugal fan
Quantity45233
Air volume-m3/h3200500088001100012500
Heater
Heat typePTC
Capacity-KW23666
Humidification
Capacity-KW11.5333

Certificates


Factory Details