2000m3/H In Row Air Conditioning Unit , Precision Air Conditioner For Server Room


Product Introduction

CoolRow is a in-row cooling solution commonly used in data centers requring higher density cooling with greater efficiency and capacity. The unit is placed beteween the servers in a row for offering cooling close to the heat load, the horizontal airflow pattern supports hot aisles and cold aisles configeration. CoolRow improves the efficiency of the overall cooling systems and ensures the steady room temperature for precise operation.


Constant temperature and humidity air conditioning units are used widely, from daily food,textile, to representatives of state-of-the-art aerospace, bio-engineering to emerge from the rapid development of the electronics industry, chemical industry from steel to precision instrument manufacturing, from hospital wards to the preparation of pharmaceutical ,all walks of life can be seen everywhere.


Due to the complexity and diversity of applications, the constant temperature and humidity unit in the structure, precision air handling with the ever-changing requirements, which requires the unit manufacturer must have the ability to respond to constant environmental design.


Benefits


Applications

  • Mobile base station
  • Outdoor rooms
  • Satellite ground station
  • Paging machine room
  • Network management center
  • Small computer room
  • A small laboratory
  • Wine cellar

Air Supply Method


Technical Parameter

ModelCRA013ACRA020ACRA040ACRA050ACRA060A
Air supplyFront/SideFront/SideFrontFrontFront
Power supply380VAC/3Ph/50Hz
Cooling capacity-KW13.226.742.653.363.9
Sensible cooling-KW13.226.742.653.363.9
Compressor
RefrigerantR410A
Quantity1
Fan
Fan typeEC Centrifugal fan
Quantity45233
Air volume-m3/h3200500088001100012500
Heater
Heat typePTC
Capacity-KW23666
Humidification
Capacity-KW11.5333

Certificates