Add to Cart
Basic 400-1500VA Line Interactive UPS With Plastic Case
High frequency online 1 kVA ~ 40 kVA Tower UPS
(1 phase input 1 single phase output, 3phase input 1 phase output,
3 phase input 3 phase output)
CNE series All intelligent high frenquency pure online UPS, which
are generally used on places required high quality electricity,such
as hospital equipments,corporations,IT loading
equipments,industrial computer terminals.As UPS inverter circuit
always in a state of work,the stored energy of UPS can be inverted
and output alternating current without switching.CNE series UPS
support different types of operation systems,apply to TCP/IP local
LAN and support the networking monitoring of UPS.
♦Support LBS synchronic control
♦Intelligent Fan speed regulation function
♦Support bypass maintenance(three phase input single phase output)
♦LCD display function,user friendly display interface
♦Three-stage extensible charging design to ensure a more remarkable
perfomnce of the batteries.
♦Support parallel opretion of more than 3 machines with shared
battery packs.
♦Support DC cold starting;without utility, the load can keep
operating with the power offered by batteries.
♦Powerful charging function is convinient to extense the capacity
of standby batteries.Intelligent charging mode even extending
battery life to cut down expenditures.
♦Support automatic restart function: when utility goes normal after
UPS is shutdown under battery mode,UPS can automatic restart.
♦Good technical indicators: the approximate 1 input power
factor,largely decreased the pollution to utility grid and improved
the use ratio of grid,so CNE series UPS are real eco-type power.
♦Support fungas proofing, moisture proofing and salt spray fog
proofing, in order to decrease or eliminate the adverse impacts of
complexing environment to electron devices;Dustproofing function
and strong envirnmental adaptability.
Function Features
♦Advanced DSP digital control technology, guarantee high UPS
performance,products stable and quality reliable.
♦Zero switching time:when the city electricity is abornomal,UPS
will turn to battery mode with zero time,which can effectively
ensure the safety and reliability of the instruments.
♦Green &Environment:Meet the State Administration of electronic
information products’ pollution control,will cause no harm to human
and envirnment under normal usage.
♦Frequency adaptive system: In order to meet different power system
requirements, it can be set to fixed or automatic idetification to
fit for 50Hz/60Hz.
♦Input power factor correction function enable the factor to be
over 0.99 to avoid grid environment pollution,so as to save energy
and decrease cost.
♦Wide input voltage and frequency range:Even in places where
electricity environment is very bad, it can also keep stable work
under utility supply mode,which decrease the number of battery
discharge and prolong the service life of batteries.
♦Powerful smart slot provide rich extending functions,can choose
SNMP network monitoring card to realise remote
supervision,management and maintenance.
Data Sheet
Model | CNE-1101 | CNE-1101L | CNE-1102 | CNE-1102L | CNE-1103 | CNE-1103L | CNE-1106 | CNE-1110 | CNE-1106L | CNE-1110L | |
Rated capacity | 1KVA/0.8KW | 2KVA/1.6KW | 3KVA/2.4KW | 6-10KVA/4.8-8KW | |||||||
Input | Voltage range | 90-285VAC | 120-274VAC | ||||||||
Frequency | 40-60HZ(adjustable) | ||||||||||
Power factor | 0.99 | ||||||||||
Output | Voltage range | 220VAC(1±2%) | 20VAC(1±1%) | ||||||||
Frequency | same as city electricity; (50±0.2)HZ in battery mode | same as city electricity; (50±0.1)HZ in battery mode | |||||||||
Power factor | 0.8 | ||||||||||
Overload capability | 125% overload, 1 min | ||||||||||
Battery | Type | Maintenance free battery | |||||||||
Voltgage | 3 of 12v/7Ah | 36VDC no battery | 6 of 12v/7Ah | 72VDC no battery | 8 of 12v/7Ah | 96VDC no battery | 16 of 12v/7Ah | 16 of 12v/9Ah | 192VDC no battery | ||
Size | (W*D*H mm) | 144*350*230 | 190*425*328 | 190*425*328 | 260*560*717 | 260*533*501 | |||||
Net weight | KG | 12 | 5.7 | 22.2 | 10 | 26.3 | 10 | 68 | 20 | ||
Communication(Standard) | RS232 communication interface |
Model | CNE-3310L | CNE-3320L | CNE-3330L | |
Capacity | 10KVA/8KW | 20KVA/16KW | 30KVA/24KW | |
Input | ||||
connection | Three phase+ ground wire | |||
rated voltage | 208/220VAC | |||
Voltage range | =-20% | |||
Frequency range | 40-70hz | |||
Power factor | >0.99 | |||
Output | ||||
output voltage | 208/220VAC | |||
Voltage accuracy | 1% | |||
Frequency accuracy | 50/60HZ±0.01HZ | |||
Waveform distortion | Linear load <2% Nonlinear load<3% | |||
Overload capability | 100%, and then switch to bypass after 1hr; 125%, and then switch to bypass after 10mins; 150%, and then switch to bypass after 1mins; | |||
Peak factor | >3:1 | |||
Switch time | 0ms(city electricity mode →battery mode) | |||
Battery | ||||
cell | 16 (16-20 adjustable) | 20 (18-20 adjustable) | ||
Charging current | 1A/2A/4A/6A/12A adjustable | |||
Display | ||||
LCD/LED | Displays input and output voltage,frequency,battery voltage and capacity, load percentage | |||
Control management | ||||
Page | intelligent RS232/USB, SNMP card(optional) | |||
Working environment | ||||
Temperature | 0℃ to 40℃ | |||
Humidity | 0 to 95% without condensation | |||
Noise(within 1m) | <58dB@1m | <60dB@1m | ||
Phisical property | ||||
Weight | Net | 16 | 22 | 22 |
Size(W*D*H) | 190*442*318 | 190*575*318 | 250*815*826 |