Add to Cart
Uninterrupted Power Supply Unit Low Frequency Industrial Ups 40kva 60kva 80kva 100KVA 120kva
1,Coolnet UPS adopt integration design concept, provide stable,
safe protection and power supply for the power input, storage and
output , to ensure the safety of loading equipment;
2.The stability of the power supply ensure the stable operation of
the loading equipment in harsh environments
3.Extreme environmental testing to ensure the stability of the
product;
4.Fault simulation test upon different environment and perfect
automatic test equipment
Smart
1.Intelligent real-time monitoring system, strongly support
customer on controlling the dynamic state of the whole system,
realize the real-time monitoring management and covers all power
supply nodes
2.Intelligent battery management, to ensure the high service life
of battery
3.The intelligent fault diagnosis, improve the efficiency of
maintenance.
Concise
1.System adopts the integrated design idea, unique design, simple
operation. Host, power supply part and intelligent monitoring
modules are all easy to install; Using full digital without
master-slave and paralleling control technology, easy expansion
2.Inner part modular, easy to install, easy to maintai
3.Many event record, easy to identify
4.Integration, easy to deliver
Economy
1.The product adopts on-line double transformation technology, low
heat release, high efficiency of the system, to save more energy
and reduce investment for customer.
2.High efficiency, ECO mode efficiency can reach up to 98%;
3.Start-up delay technology, reduce the Instantly shocks on power
distribution system, then to reduce customer investment
4.Low input current harmonics, improve the utilization rate of
power supply
Reliability
1.Redundancy design of key part, improve the reliability of system,
ensure the reliable power supply system
2.Unique system design, multiple protection system design to ensure
high reliability of the system in harsh environments
3.Output isolation design, reduce the effect on the load and ensure
the safety of the loading equipment
4.Key parts adopt international famous brand, to ensure product
quality.
5.24 hours continuous working and related verification test, ensure
the high reliability of the system.
Optional part
Model | 30 | 40 | 60 | 80 | 100 | 120 | 160 | ||
Capacity | Rated capacity | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | |
Active power | 27KW | 36KW | 54KW | 72KW | 90KW | 108KW | 144KW | ||
Mian line | Input method | Three phase+ ground wire | |||||||
Rated AC input | 380/400/415VAC | ||||||||
Voltage range | 285VAC - 498VAC | ||||||||
Rated frequency | 50/60HZ | ||||||||
Frequency range | 45 - 65HZ | ||||||||
Input power soft start | 5 - 600 seconds configurable | ||||||||
Power factor | 0.95(add input harmonic wave filter) | ||||||||
Bypass | Rated AC input | 380/400/415VAC three phase+ zero line( three phase+zero line+ ground line) | |||||||
Voltage range | ±10%,±15%,±20% configurable | ||||||||
Frequency range | 50/60HZ±10% | ||||||||
Output | Rated AC output | 380/400/415VAC | |||||||
Stable voltage accuracy | ±1% (Balanced load) ±2%(Unbalanced load) | ||||||||
Power factor | 0.9 | ||||||||
Dynamic voltage transient | ±5%(0 - 100% load change) | ||||||||
THDU | <1%(100% linear load) <3%(100% non-linear load) | ||||||||
Voltage dynamic response time | <5ms | ||||||||
Synchronizing range | ±5% | ||||||||
Inverter overload capability | When output power factor is 0.9: 105% long time working; 110% for 1 hour; 125% for 10 minutes; 150% for 1 minute | ||||||||
Frequency accuracy | ±0.05% | ||||||||
Wave form | Pure sinusoidal wave | ||||||||
Invert mode | 92% | 94% | |||||||
Efficiency | ECO mode | 97% | 98% | ||||||
Parallel quantity | 8 pieces at most | ||||||||
N+X in parallel | Battery quantity | 12V,32 cells(30-34 adjustable) | |||||||
Battery | Panel display | LCD+LED | |||||||
Display | Depth(mm) | 720 | 750 | 855 | |||||
Size | Height(mm) | 1100 | 1400 | 1900 | |||||
Width(mm) | 6 pulse | 560 | 800 | 890 | 1245 | ||||
12 pulse | 970 | 1270 | 1415 | 1770 | |||||
Weight | Net weight | 6 pulse | 300 | 330 | 480 | 550 | 960 | 1075 | |
12 pulse | 420 | 480 | 750 | 800 | 1390 | 1685 | |||
Using environment | Temp. | 0 - 40℃ | |||||||
Humidity | 0-95% with no condensation | ||||||||
Noise(1m) | <55dB | <67dB | |||||||
Control management | RS-232/USB optional | Support windows2000/xp/7/Linux/Mac | |||||||
SNMP optional | Support SNMP administrator and network browser for electricity management | ||||||||
Standard | Safety standard | IEC60950-1,IEC62040-1-1 | |||||||
Electromagnetic compatibility | IEC62040-2,IEC62040-3 |
Model | 200 | 250 | 300 | 400 | 500 | 600 | 800 | ||
Capacity | Rated capacity | 200KVA | 250KVA | 300KVA | 400KVA | 500KVA | 600KVA | 800KVA | |
Active power | 180KW | 225KW | 270KW | 360KW | 450KW | 540KW | 720KW | ||
Mian line | Input method | Three phase+ ground wire | |||||||
Rated AC input | 380/400/415VAC | ||||||||
Voltage range | 285VAC - 498VAC | ||||||||
Rated frequency | 50/60HZ | ||||||||
Frequency range | 45 - 65HZ | ||||||||
Input power soft start | 5 - 600 seconds configurable | ||||||||
Power factor | 0.95(add input harmonic wave filter) | ||||||||
Bypass | Rated AC input | 380/400/415VAC three phase+ zero line( three phase+zero line+ ground line) | |||||||
Voltage range | ±10%,±15%,±20% configurable | ||||||||
Frequency range | 50/60HZ±10% | ||||||||
Output | Rated AC output | 380/400/415VAC | |||||||
Stable voltage accuracy | ±1% (Balanced load) ±2%(Unbalanced load) | ||||||||
Power factor | 0.9 | ||||||||
Dynamic voltage transient | ±5%(0 - 100% load change) | ||||||||
THDU | <1%(100% linear load) | <2%(100% linear load) | |||||||
<3%(100% non-linear load) | |||||||||
Voltage dynamic response time | <5ms | ||||||||
Synchronizing range | ±5% | ||||||||
Inverter overload capability | When output power factor is 0.9: 105% long time working; 110% for 1 hour; 125% for 10 minutes; 150% for 1 minute | ||||||||
Frequency accuracy | ±0.05% | ||||||||
Wave form | Pure sinusoidal wave | ||||||||
Efficiency | Invert mode | 94% | |||||||
ECO mode | 98% | ||||||||
N+X in parallel | Parallel quantity | 8 pieces at most | |||||||
Battery | Battery quantity | 12V,32 cells(30-34 adjustable) | 12V,40 cells | ||||||
Display | Panel display | LCD+LED | |||||||
Size | Depth(mm) | 855 | |||||||
Height(mm) | 1900 | ||||||||
Width(mm) | 6 pulse | 1245 | 1640 | 2265 | |||||
12 pulse | 1770 | 2265 | 2265 | 2700 | 3000 | 3800 | |||
Weight | Net weight | 6 pulse | 1075 | 1630 | 2105 | ||||
12 pulse | 1685 | 2290 | 2500 | 3000 | 3500 | 4100 | |||
Using environment | Temp. | 0 - 40℃ | |||||||
Humidity | 0-95% with no condensation | ||||||||
Noise(1m) | <67dB | <71dB | <73dB | <76dB | |||||
Control management | RS-232/USB optional | Support windows2000/xp/7/Linux/Mac | |||||||
SNMP optional | Support SNMP administrator and network browser for electricity management | ||||||||
Standard | Safety standard | IEC60950-1,IEC62040-1-1 | |||||||
Electromagnetic compatibility | IEC62040-2,IEC62040-3 |