ISO9001 Data Center Server Rack Mount Air Conditioner

Brand Name:Coolnet
Certification:CE/ISO9001
Model Number:CI05,09
Minimum Order Quantity:1
Delivery Time:4W
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

In-Rack Cooling In Server Rooms & Data Centers For Server Cabinet Cooling


Product Introduction

In-Rack is the most precise cooling available, as the rack and the air conditioner operate in a closed relationship with one another. Cold air has no choice but to pass through the servers; hot air has no choice but to pass through the heat exchanger. In-Rack cooling provides a computing environment-a microclimate-that is thermally neutral to the rest of the room.

The In-Rack split type air conditioner power supply is 220VAC, focus on mini-ICT room heat management, which widely used for small scade IT equipment cooling for middle size of enterprises etc.


Feature & Benefits

Scope of Application

  • Micro Data C enter
  • Single row cabinet
  • Modular Computer Rooms
  • Medium and high heat density computer room
  • Modular Data Center
  • IT Rack for Blade Servers

Air Supply Method

Product Advantages


Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function;
* Strict process control and famous brand components to ensure high quality and reliability
of this product;
* Fit for harsh condition (T3), R134a refrigerant ;
* Multiple self-protection design , RS485 communication port (MODBUS-RTU protocol);
* LED display, all the settings can changed at the field;
* Built-in condensate water evaporating device;
* Dry contact alarm output, NO/NC optional;

Indoor Unit Parameters

Model-CJA0003000500070012
Phase/Function1.5P,Single Phase2P,Single Phase3P,Single Phase5P,Single Phase
Parameters
Cooling capacity kW3.557.512.5
Sensible cooling capacity kW 3.557.512.5
Air volume m³/h800115016002300
Sensible heat ratio %100100100100
Heating kW (Option)1123
Maximum operating current A15152534
Power Cord Cable Specificationsmm 3×2.53×2.53×43×6
Indoor/outdoor unit shut-off valve
Refrigerant gas pipe φ mm12.712.712.715.88
Refrigerant liquid pipe φ mm9.529.529.529.52
Indoor unit structural parameters
Dimension:W×D×H mm442×714×175 (4U)
442×714×218 (5U)
442×714×218 (5U)442×714×351 (8U)442×714×440 (10U)
Outdoor Unit
Type-CJT3005300530083013
Quantity1111
Note 1: Under standard conditions, the indoor dry bulb temperature is 37°C, the wet bulb temperature is 21°C, and the outdoor dry bulb temperature is 35°C;
Note 2: The above table is only part of the parameters, the specific configuration is subject to the actual purchase of the nameplate.

Outdoor Unit Parameters

Type- CJT3005300530083013
Power supply220Vac/1Ph/50Hz
InstallationVertical
Speed modeStepless speed regulation
Noise dBA54555658
Rated current A661015
Power Cord Cable Specificationsmm 4×1.54×1.54×2.54×4
Communication cable specificati mm (with shielding function)on 3×13×13×13×1
Structural parameters of outdoor unit
Dimension:W×D×H mm840×285×610840×285×610880×360×800930×390×1270

① The power cord of the outdoor unit must be connected from the indoor unit;

②The ex-factory unit is not equipped with a 4.3-inch touch screen, and needs to be purchased separately.