Micro All In One Data Center For Complex Environment High Dust Proof

Brand Name:COOLNET
Certification:CE ISO
Model Number:ERX EC12
Minimum Order Quantity:1PCS
Delivery Time:20-35working days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Micro All In One Data Center For Complex Environment With High Dust-Proof Level


Product Introduction

What is an all-in-one cabinet? The integrated cabinet is an in-depth integration of data center infrastructure products, including UPS, power distribution, refrigeration, fire protection and other subsystems, through the monitoring system to complete the overall management of all systems, simplifying the planning and construction process. The reliable UPS power distribution system continuously escorts the IT equipment, and at the same time is equipped with a good cooling system to ensure the operating environment of the IT equipment, the deployment of the dynamic ring monitoring system, and the real-time monitoring of the operating status of the equipment. Coolnet all-in-one cabinets are popular among small and medium-sized enterprises due to their small footprint, long service life and low cost.

Feature


Integrated wiring

  • Meet the provisions of 4.5 in YD/T1272.1-2003
  • Closed box, more beautiful wiring
  • Tool-less enclosure cover
  • Compact size, suitable for many occasions

Cooling system

  • Rack mounted precision air conditioner(Dimension: 7X24X365)
  • 3.5-10.5KW cooling capacity, accuracy ±0.5℃
  • Inverter compressor + double EC fan, PUE≤1.4
  • The noise of the whole machine is less than or equal to 49dB
  • Low-load anti-condensation technology
  • N+X redundant group control

UPS system

  • Option cappacity: 3-30KVA
  • Rack mounted UPS
  • Backup time can be customized on demand (15-120m)
  • ATS dual input switching (optional)
  • Industrial grade device, built-in C-level lightning protection

Advantages

Intelligence
Coolnet can realize 365 days 7X24 hours unattended, remote monitoring and intelligent humanized management. Minimize IT deployment and operation and maintenance costs.


Dust-proof
The biggest advantage of the mini-intelligent computer room is enclosed and dust-proof. The internal air of the computer room can reach the air cleanliness standard of the A-level computer room, the failure rate of IT equipment is greatly reduced, and the life cycle is extended by 1 to 2 times.


Noise
Noise test case: Place 4 rack-mounted servers, 2 switches and other equipment in a common cabinet, and the test room noise is about 75dB;
The same IT equipment is placed in the MICROOM, the test noise is reduced to about 50dB, the noise intensity is reduced by 25 dB, and the noise reduction is about 85%.


Application

  • Edge Computing
  • As a computing node in remote
  • Business outlets (telecommunications, finance, energy, radio and television, retail...)
  • Small companies

Technical Parameter

ModelEC08EC12EC20ERx
Power3KVA3-6KVA6-30KVA
Number of cabinets0.8m high cabinet, available space 8U1.2m high cabinet, available space 16UStandard 42U cabinet, free space 30U2-10 standard 42U glass door cabinets
Enclosed cabinetGlass door, IP5X, full cold and hot channel sealing
Power supply220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
RefrigerationUnique air duct design, without air conditioner and outdoor unitRefrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring