2 Way C13 12 Way C19 PDU With Master Switch

Brand Name:COOLNET
Certification:UL CAS
Model Number:Smart PDU
Minimum Order Quantity:1 unit
Delivery Time:15 days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

2 Way C13 12 Way C19 PDU With Master Switch


Product Introduction

PDUs are often referred to as power distribution sockets for cabinets. PDUs are products designed to provide power distribution for electrical equipment installed in cabinets. They have various series of specifications with different functions, installation methods and different socket combinations. The power environment provides a suitable rack-mounted power distribution solution. When the socket becomes neccessary in the computer room, it cannot meet the needs of the environment. When the high-power equipment is everywhere, its operation is limited due to the socket. Messy and unsightly computer rooms would cause lots of hidden danger. Therefore, high quality PDU protection should be needed.

Technical Features

1) Internal connection:
The connections between socket modules are all connected by screw terminals and plug-in terminals, and there are convenient devices such as fixing bolts for fixing cables at the ends of the sockets. The socket reed is phosphor bronze, with excellent contact and good elasticity, and can withstand more than 10,000 hot swaps;


2) Intelligence
easy management and remote control: optional additional functions such as digital display, abnormal alarm, network management, etc., highlight the intelligence of the product, improve its usability and manageability; security protection


3) Multiple circuit protection
lightning strike, surge protection: maximum impact current: 20KA or higher, limit voltage: less than or equal to 500V or lower.


Application

  • Communication industry
  • Security system
  • IDC engine room
  • Electric power system
  • Track traffic
  • Enterprise small and medium data center
  • Office scene
  • Dispatch center

Parameter


PDU


Parameters


input

Input typeAC single phase, AC three phase,-48VDC,240VDC,336VDC
Input mode

Transparent open type junction box,power cord, cable,

industrial connector, socket etc.

Input voltage range100-277VAC/312VAC-418VAC/11VDC-240VDC/-43VDC- -56VDC
AC input frequency50/60Hz
total load currentMAX 63A

Output

Storage temperature-40 - +70
Relative humidity5-95% (No condensation)
Atmospheric pressure70kPa - 106kPa
Working altitudeNo more than 4000M

Environmental

Working temperature-10 - +75
Storage temperature-40 - +80
Relative humidity5-95% (No condensation)
Working altitudeNo more than 4000M
IP ratingIP20
Protectioninput protection moduleCircuit breaker, lightning protection, leakage protector, temperature insepction module (optional)
Output protection moduleCircuit breaker, fuse box, fuse(optional)

Installation method


Certification

Case

Factory