EC Fan Row Cool Air Conditioner Used In Internet Data Centers


Product Introduction

COOLNET Row Cooling Precision Air Conditioning is an ideal product for in row cooling in green data centers. It has the industry's best cooling efficiency. The variable frequency scroll compressor uses environmentally friendly refrigerant R410A. It has excellent intelligent control and performance. Flexible cooling capacity design: can be used in 20%~100% adjustment of cooling capacity, which greatly improves the energy efficiency of ordinary air-cooled units by 33.3%~50%. The 7-inch touch screen can comprehensively display various data in the computer room and related working conditions of the unit.


Advantage

● Select key components of international famous brands, such as valley wheel compressor, Danfoss compressor, EBM or Xerox EC fan, Danfoss refrigeration valve parts, etc.
● A variety of configuration types, can choose single cold type, single cold + electric auxiliary heat type, constant temperature and humidity type, to meet the needs of different environmental applications;
● Close to the heat source refrigeration, return air temperature is high, heat exchange temperature difference is large, refrigeration efficiency is high, shorten the air transmission distance, reduce the air flow cold loss and cold and hot air mixing;
● EC fan, can achieve variable air volume regulation, dehumidification mode or down to low wind speed operation;
● Adopt multi-fan design, the fan runs at the best efficiency point, and meets the redundancy backup;
● Adjustable air duct, according to the needs of the site, flexible adjustment of the direction of the air; Provides two types of configurations: upper takeover and lower takeover. You can choose the takeover direction flexibly according to site installation conditions.
● Optional condensate drainage pump to meet the application requirements of upper drainage;
● With the function of starting from the call, after the call automatically restored to the running state before the power failure;
● Standard RS485 communication interface, can provide communication protocol;
● Large area heat exchanger, from top to bottom, from left to right full, uniform air flow, high heat exchange efficiency;



Technical Parameter


ModelCRA013ACRA020ACRA040ACRA050ACRA060A
Air supplyFront/SideFront/SideFrontFrontFront
Power supply380VAC/3Ph/50Hz
Cooling capacity-KW13.226.742.653.363.9
Sensible cooling-KW13.226.742.653.363.9
Compressor
RefrigerantR410A
Quantity1
Fan
Fan typeEC Centrifugal fan
Quantity45233
Air volume-m3/h3200500088001100012500
Heater
Heat typePTC
Capacity-KW23666
Humidification
Capacity-KW11.5333