Add to Cart
Remote Network Monitoring With Close Control Units Air Conditioning
Products Introduction
Close control unit air conditioners are generally used in machine rooms, laboratories, electrical equipment and other precision occasions, with large air supply volume and good air circulation. Due to its special air filter, it can filter out the dust in the air in a timely and efficient manner to keep the machine room clean. It is a precision system engineering, which not only regulates the room temperature, but also maintains the indoor humidity requirement. Industrial precision air conditioning is a precision system engineering, which not only regulates the room temperature, but also maintains the requirements of indoor humidity. The reliable components and efficient cooling system of industrial precision air conditioners ensure stable and efficient operation of the server room throughout the year. Maintaining temperature and humidity design conditions is essential for the smooth operation of the data room. |
Product functions
Easy operation and maintenance design Pathfinder unit is compact, needs a small space for maintenance and standing:Full front access maintenance, with easy to open the front panel design. Modular design for easy handling and installation Super convenient piping connections, the unit is charged with refrigerant at factory,no need of welding at job site,pipes between indoor and outdoor unit are connected with screws. Remote network monitoring With RS485 interface to monitor machine operation condition and ready to perform remote control and status adjusting for local and remote control modes, enabling four remote functions (remote signals, remote control, remote adjustment. remote test)and has a good electrical isolation properties |
Air Supply Method
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |
Case