CCU Air Conditioning For Modular Design For Easy Handling And Installation
Products Introduction
Close control unit air conditioners are generally used in machine rooms, laboratories, electrical equipment and other precision occasions, with large air supply volume and good air circulation. Due to its special air filter, it can filter out the dust in the air in a timely and efficient manner to keep the machine room clean. It is a precision system engineering, which not only regulates the room temperature, but also maintains the indoor humidity requirement. Industrial precision air conditioning is a precision system engineering, which not only regulates the room temperature, but also maintains the requirements of indoor humidity. The reliable components and efficient cooling system of industrial precision air conditioners ensure stable and efficient operation of the server room throughout the year. Maintaining temperature and humidity design conditions is essential for the smooth operation of the data room. Feature & Benefits |
Function Description
|
Advantage
Quick response. Real-time monitoring of environmental temperature and humidity changes, quickly adjust the output of cooling, heating, humidification, and dehumidification to adapt to the load demand. High quality accessories. The unit adopts high-quality components such as page flow inverter compressor, EC fan, electronic expansion valve, SCR electric heating, etc. to ensure the stable performance of the whole machine. Human-machine interface is friendly. 7-inch touch screen controller,easy to set up, with monitoring and group control functions, to meet the various needs of users. Fault detection and alarm functions When machine fails,failure status will be self diagnosed to continue to run or stop,and send remote communication alarm. Seismic design Using a special structure design, passing vibration testing to garuantee the reliability of its performance Dual automatic switching function Automatically switch on standby unit after master unit keeps working for the set time. The standby unit continues the master unit's operating mode and speed to maintain the set temperature before switching status(sent from the master),and so forth, master and standby unit work in redundant. |
Applications
|
Air Supply Method
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |