Environmental Control Data Center Air Conditioner Closed Control Unit Precision

Brand Name:Coolent
Certification:ISO/CE
Model Number:CYAT100D/U
Minimum Order Quantity:1Unit
Delivery Time:20-30Days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Environmental Control Data Center Precision Air Conditioner closed control unit


Products Introduction

Coolnet focuses on the R&D, production, and application of data center integrated solutions. As technical consulting, product supply, system integrator, and service provider, it is committed to serving customers in the fields of communication equipment rooms, data centers, smart construction, and energy management.


CyberMaster series precision air conditioning system adopts international cutting-edge constant temperature and constanthumidity technology, which is designed and developed for a precision environment.


Advantage


Precise temperature and humidity Control

CyberMaster has a constant temperature and humidityfunction, temperature control accuracy of ±1℃, and relative humidity control accuracy of±5%.

Temperature control accuracy can reach ±0.1℃and relative humidity control accuracy can reach±2%. for laboratory, warehouse, and so on.


High Adaptability

Multi-air discharge choices including Down flow and Up flow and so on. Multiple monitoring interface.Suitable for various ambient temperature(Optional low temperature kits).

Customized design available.


High Energy Efficiency

Copland Efficient and quiet flexible scroll compressor. Efficient EC fan, continuous airflow adjustment. Controller ensures optimum cooling efficiency. Electrode humidifier to realize precise humidity control. Precision Electronic Expansion Valve precision cooling control.


Applications


„ Computer room and data center

„ Switch room and mobile center station in telecommunication

„ High-tech environment and lab

„ Industrial automation control room and precision manufacturing workshop

„ Standard test room and calibration center

„ UPS and battery room

„ Test room in hospital

„ Biochemical culture chamber


Refrigeration mode


Air Cooled

The air flow in the room is driven by the unit's indoor fan, during which the indoor air flows through the air conditioning evaporator, transferring heat to the refrigerant, which is transported to the outdoors via the refrigeration system piping and disperses the heat to the outdoor environment through the condenser. The air conditioning unit and the outdoor condenser are connected by closed refrigeration ducts.


Air discharge

The CyberMaster series units are available in a variety of Air discharge, which can be selected by the user according to the specific use.



Technical Parameters


Model: CYAT41D/UT45D/UT50D/UT55D/UT61D/UT70D/UT76D/UT85D/UT90D/UT100D/U
Power Supply380V 3Ph-50HZ
Air DischargeUpflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1)KW41.945.350.555.461.470.576.285.590.8102
SensibleKW38.842.547.851.657.565.271.279.584.595.7
Max Operation CurrentA60.162.164.368.673.584.691.195.7103.5110.7
AEERW/W3.63.63.73.73.63.63.63.63.63.6
Air Flowm3/h11500130001550016000175001850020500225002350024200
CompressorHermetic scroll
RefrigerantR410A
Compressor quantityPC2222222222
Fan SectionCentrifugal EC fan
Fan quantityPC1111223333
Rated currentA4.44.44.455.25.26.516.516.516.5
Rated powerW1800200020003000330039003900540063006300
Excess press outside(2)Pa
Fin coil evaporator
Fin pitchmm1.8
Air filterStandard EN799
Level≥G4
Dust interception rate>95%
Fire resistance level1
Reheat Section
Total heating capacityKW9999999151515
MaterialPTC
Humidifier SectionElectrode type
CapacityKg/h13131313131313131313
Rated CurrentA15151515151515151515
Physical
Lengthmm1315131513151315179017902190219021902190
Depthmm980980980980980980980980980980
Heightmm1975197519751975197519751975197519751975
WeightKG485485492518625655655708716735
Connection Pipe Size
Liquid pipemm22222222222828282828
Gas Pipemm28282828283535353535
Inlet Pipe of Humidifier(Female)InG1/2''G1/2''G1/2''G1/2''G1/2''G1/2''G1/2''G1/2''G1/2''G1/2''
Drain Pipe-IDmm25252525252525252525
Breakers Cables
Recommended Breaker (Indoor Unit)A808080100100125125150150150
Cables(Indoor Unit)mm24*16+ 1*104*16+1*104*16+1*104*16+1*104*16+1*103*25+2*163*25+2*163*25+2*163*50+2*253*50+2*25
Condenser (CY)2*03512*03512*04512*04512*05222*05822*06622*06622*07422*0832

Certificates



Packing & Delivery



Efficient EC fan, continuous airflow adjustment

Controller ensures optimum cooling efficiency

Electrode humidifier to realize precise humidity control

Precision Electronic Expansion Valve precision cooling control

China Environmental Control Data Center Air Conditioner Closed Control Unit Precision supplier

Environmental Control Data Center Air Conditioner Closed Control Unit Precision

Inquiry Cart 0