Add to Cart
Environmental Control Data Center Precision Air Conditioner closed control unit
Products Introduction Coolnet focuses on the R&D, production, and application of data center integrated solutions. As technical consulting, product supply, system integrator, and service provider, it is committed to serving customers in the fields of communication equipment rooms, data centers, smart construction, and energy management. CyberMaster series precision air conditioning system adopts international cutting-edge constant temperature and constanthumidity technology, which is designed and developed for a precision environment. Advantage Precise temperature and humidity Control CyberMaster has a constant temperature and humidityfunction, temperature control accuracy of ±1℃, and relative humidity control accuracy of±5%. Temperature control accuracy can reach ±0.1℃and relative humidity control accuracy can reach±2%. for laboratory, warehouse, and so on. High Adaptability Multi-air discharge choices including Down flow and Up flow and so on. Multiple monitoring interface.Suitable for various ambient temperature(Optional low temperature kits). Customized design available. High Energy Efficiency Copland Efficient and quiet flexible scroll compressor. Efficient EC fan, continuous airflow adjustment. Controller ensures optimum cooling efficiency. Electrode humidifier to realize precise humidity control. Precision Electronic Expansion Valve precision cooling control. |
Applications Computer room and data center Switch room and mobile center station in telecommunication High-tech environment and lab Industrial automation control room and precision manufacturing workshop Standard test room and calibration center UPS and battery room Test room in hospital Biochemical culture chamber Refrigeration mode Air Cooled The air flow in the room is driven by the unit's indoor fan, during which the indoor air flows through the air conditioning evaporator, transferring heat to the refrigerant, which is transported to the outdoors via the refrigeration system piping and disperses the heat to the outdoor environment through the condenser. The air conditioning unit and the outdoor condenser are connected by closed refrigeration ducts. Air discharge The CyberMaster series units are available in a variety of Air discharge, which can be selected by the user according to the specific use. |
Technical Parameters
Model: CYA | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | ||||||||||
Air Discharge | Upflow/Downflow | ||||||||||
Cooling Capacity :24℃/50%RH | |||||||||||
Total Capacity (1) | KW | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
Max Operation Current | A | 60.1 | 62.1 | 64.3 | 68.6 | 73.5 | 84.6 | 91.1 | 95.7 | 103.5 | 110.7 |
AEER | W/W | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor | Hermetic scroll | ||||||||||
Refrigerant | R410A | ||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section | Centrifugal EC fan | ||||||||||
Fan quantity | PC | 1 | 1 | 1 | 1 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Excess press outside(2) | Pa | ||||||||||
Fin coil evaporator | |||||||||||
Fin pitch | mm | 1.8 | |||||||||
Air filter | Standard EN799 | ||||||||||
Level | ≥G4 | ||||||||||
Dust interception rate | >95% | ||||||||||
Fire resistance level | 1 | ||||||||||
Reheat Section | |||||||||||
Total heating capacity | KW | 9 | 9 | 9 | 9 | 9 | 9 | 9 | 15 | 15 | 15 |
Material | PTC | ||||||||||
Humidifier Section | Electrode type | ||||||||||
Capacity | Kg/h | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Physical | |||||||||||
Length | mm | 1315 | 1315 | 1315 | 1315 | 1790 | 1790 | 2190 | 2190 | 2190 | 2190 |
Depth | mm | 980 | 980 | 980 | 980 | 980 | 980 | 980 | 980 | 980 | 980 |
Height | mm | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 |
Weight | KG | 485 | 485 | 492 | 518 | 625 | 655 | 655 | 708 | 716 | 735 |
Connection Pipe Size | |||||||||||
Liquid pipe | mm | 22 | 22 | 22 | 22 | 22 | 28 | 28 | 28 | 28 | 28 |
Gas Pipe | mm | 28 | 28 | 28 | 28 | 28 | 35 | 35 | 35 | 35 | 35 |
Inlet Pipe of Humidifier(Female) | In | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' |
Drain Pipe-ID | mm | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 |
Breakers Cables | |||||||||||
Recommended Breaker (Indoor Unit) | A | 80 | 80 | 80 | 100 | 100 | 125 | 125 | 150 | 150 | 150 |
Cables(Indoor Unit) | mm2 | 4*16+ 1*10 | 4*16+1*10 | 4*16+1*10 | 4*16+1*10 | 4*16+1*10 | 3*25+2*16 | 3*25+2*16 | 3*25+2*16 | 3*50+2*25 | 3*50+2*25 |
Condenser (CY) | 2*0351 | 2*0351 | 2*0451 | 2*0451 | 2*0522 | 2*0582 | 2*0662 | 2*0662 | 2*0742 | 2*0832 |
Certificates
Packing & Delivery
Efficient EC fan, continuous airflow adjustment
Controller ensures optimum cooling efficiency
Electrode humidifier to realize precise humidity control
Precision Electronic Expansion Valve precision cooling control