Rack Mount Uninterruptible Power Supply UPS System For Computer Room Energy Backup

Brand Name:COOLNET
Certification:CE,ISO
Model Number:CNER01-CNER20
Minimum Order Quantity:5units
Delivery Time:5-10 working days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Online Rack Mount Uninterruptible Power Supply Ups 1KVA 3KVA 6kva 10kva 15kva 20kva


High frequency on line 1 kVA ~ 20 kVA ( single phase inlet and single phase
outlet/three phase inlet and single phase outlet/three phase inlet and three phase outlet)


Flexible, reliable and perfect compatible server cabinet.


Coolnet rack type UPS is the double transformation on-line technology, support more than 3 sets parallel work, and support the function of sharing battery pack when in parallel mode; online UPScan provide the optimal power environment for the load. Regardless of voltage accuracy, input noise filtering, zero switching time and compatible with the standard terms of service cabinet, Rack UPS is the best choice.

Character and Advantage

♦Support LBS control in sync;
♦​Have the function of fan speeding control with intelligence;
♦​Comprehensive electrical isolation protection and bypass protection;
♦​Support bypass maintenance (three phase inlet and single phase outlet/three phase inlet and three phase outlet);
♦​Large LCD Chinese/English display interface, user friendly;
♦​Make automatic alarm, self-detection, find problems easily in time come true;
♦​Three - stage extended charge design to ensure superior battery performance;
♦​Only online UPS, and output high quality sine wave power that provide the user a better power supply protection;
♦​Wider range of input voltage that working under large fluctuations grid environment, can be in commercial power
♦​mode without switching to battery mode, which can protect the battery lifespan


Design Concept

♦Long-term power supply design

Rack UPS provide long backup time unit for users to choose: through configure different battery pack capacities, can meet the user's requirements for different backup time.

♦Can be used with large motor

Wide input voltage and frequency range that make Rack UPS compatible with main brand generator. It expand the application environment, meanwhile effectively remove the harmful power made by the generator, also supply a pure, safe and stable power for the load.

Configure standard battery module

Rack UPS configured standard battery module(For user selection). Standard battery modules are used in high quality VRLA maintenance free lead-acid battery, with high battery quality to ensure the safety and reliability of UPS using.

♦Zero transition time

When the city power outage or recovery, it do not need conversion time for the Rack UPS switching between the power mode and the battery mode, thus effectively ensuring the reliability of load operation and data storage.

Input power factor correction

Rack UPS have Input power factor correct function, the Input power factor can reach to above 0.99% under full loading condition,which protect use's grid environment from pollution.

♦DC Start

In the case of power cut, if need to start computer or other load devices by Rack UPS,Rack UPS can use battery to carry on DC Start, so that make the use of Rack UPS more convenient and reliable.

♦Auto restart function

Once the city power abnormal, it will enter into battery mode to supply power until the end of power supply, then the Rack UPS will shut down automatically; after the city power back to normal, UPS will activate

♦Configure smart slot

Rack UPS equipped with an intelligent slot,users can purchase SNMP card or other general accessories. Make centralized monitoring and remote management functions come true through SNMP internet management.


Data Sheet

ModelCNER-1101(L)CNER-1102(L)CNER-1103(L)CNER-1106LCNER-1110L
Capacity1KVA/0.8kW2KVA/1.6kW3KVA/2.4kW6KVA/4.8kW10KVA/8kW
Input
Connection ModeSingle Phase + Ground
Input Voltage200/208/220/230/240VAC
Voltage Range100~300VAC
Frequency40~70Hz
Power factor>0.99
Output
Output Voltage200/208/220/230/240VAC
Voltage regulation±1%
FrequencySynchronous correction range46~54Hz/56~64Hz
Battery Model50Hz±0.1Hz/60Hz±0.1Hz
Distortion (THDU)≤0.3%
Peak Coefficient≥3:1
Overload Capacity110%,convey to bypass after 1h;125%,convey to bypass after 10min;150%,convey to bypass after 1min.
Time switchingElectric City/Battery0ms
Inverter/Bypass<4ms (standard environment)0ms
Battery
Standard MachineBattery Cells246/
Charging Current1.0A (Max)/
Battery Model12V,9Ah/
Long LastingBattery Cells36816(16-20 optional)
Charging Current1A/2A/4A/6A settable
Battery ModelDepends on the applicant
Efficiency
City Electricity Model>91%>93%
Battery Model>91%>93%
Display Interface
LCD/LEDLoading Size, Battery Capacity, City Electricity Mode, Battery Mode, Bypass Mode, Fault Indication
Control Management
Intelligent RS-232/USBSupport Windows 2000/2003/XP/Vista/2008,Windows 7/8,Linux,Unix and MAC
Option SNMPSupport SNMP Internet Management
Environment
Temperature0~40℃
Relative Humidity0~95% (Non Condensing)
Noise<50dB@1m<55dB@1m<58dB@1m
Physical Character
Standard MachineSize: Width*Depth*Height(mm)438*310*88438*410*88438*630*88//
Net Weight(kg)121829//
Long LastingSize:Width*Depth*Height(mm)438*310*88438*410*88438*530*88438*580*133
Net Weight(kg)5781216

ModelCNER-3110LCNER-3115LCNER-3120L
Capacity10kVA/8kW15kVA/12kW20kVA/16kW
Input
Connection ModeThree-phase + four wire
Rated Voltage380/400/415VAC
Voltage Range285~520VAC@100%Load; 176~520VAC@50%Load
Frequency40~70Hz
Power factor≥0.99
Output
Output Voltage200/208/220/230/240VAC
Voltage regulation±1%
FrequencySynchronous correction range46~54Hz/56~64Hz
Battery Model50Hz±0.1Hz/60Hz±0.1Hz
Distortion (THDU)≤2%( Linear load ), ≤3% ( Non-liner load )
Distortion (THDU)≤0.3%
Peak Coefficient≥3:1
Overload Capacity110%, convey to bypass after 1h; 125%, convey to bypass after 10min; 150%, convey to bypass after 1min.
Time switchingElectric City/Battery0ms
Inverter/Bypass0ms
Battery
Battery Cells20
Charging Current1A/2A/4A/6A Settable
Battery ModeDepends on the applicant
Efficiency
City Electricity Mode / Battery Mode≥93%
ECO Mode≥96%
Display Interface
LCD/LEDLoading Size, Battery Capacity, Electric City Mode, Battery Mode, Bypass Mode, Fault Indication
Control Management
Intelligent RS-232/USBSupport Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix and MAC
Option SNMPSupport SNMP Internet Management
Environment
Temperature0~40℃
Relative Humidity0~95% (Non Condensing)
Noise<60dB@1m<65dB@1m
Physical Character
Size: Width*Depth*Height(mm)438*668*133438*668*266
Net Weight(kg)2245
ModelX1-3110LX1-3115LX1-3320L
Capacity10kVA/8kW15kVA/12kW20kVA/16kW
Input
Connection ModeThree-phase + four wire
Rated Voltage380/400/415VAC
Voltage Range285~520VAC@100%Load; 176~520VAC@50%Load
Frequency40~70Hz
Power factor≥0.99
Output
Output Voltage380/400/415VAC
Voltage regulation±1%
FrequencySynchronous correction range46~54Hz/56~64Hz
Battery Model50Hz±0.1Hz/60Hz±0.1Hz
Distortion (THDU)≤2 %( Linear load ), ≤3% ( Non-liner load )
Distortion (THDU)≤0.3%
Peak Coefficient≥3:1
Overload Capacity110%, convey to bypass after 1h; 125%, convey to bypass after 10min; 150%,convey to bypass after 1min.
Time switchingElectric City/Battery0ms
Inverter/Bypass0ms
Battery
Battery Cells20
Charging Current1A/2A/4A/6A Settable
Battery ModeDepends on the applicant
Efficiency
City Electricity Mode / Battery Mode≥93%
ECO Mode≥96%
Display Interface
LCD/LEDLoading Size, Battery Capacity, Electric City Mode, Battery Mode, Bypass Mode, Fault Indication
Control Management
Intelligent RS-232/USBSupport Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix and MAC
Option SNMPSupport SNMP Internet Management
Environment
Temperature0~40℃
Relative Humidity0~95% (Non Condensing)
Noise<60dB@1m<65dB@1m
Physical Character
Size: Width*Depth*Height(mm)438*668*133438*668*266
Net Weight(kg)4346
China Rack Mount Uninterruptible Power Supply UPS System For Computer Room Energy Backup supplier

Rack Mount Uninterruptible Power Supply UPS System For Computer Room Energy Backup

Inquiry Cart 0