Add to Cart
Glass curtain wall construction technology
1. Process characteristics
1.1 The glass is fixed on the sub-frame with silicone structural
sealant, and the sub-frame is fixed to the main frame (column,
beam) by mechanical clamping. The structural glass assembly
components are completely separated from the main frame, which is
one of the biggest features of the hidden frame glass curtain wall
component construction.
1.2 The structural glass assembly components are produced in a
professional production workshop. The quality of the glue and the
processing accuracy are guaranteed, and the silicone structural
sealant is saved.
1.3 Columns and beams are cut by the manufacturer, with high
processing accuracy and less material waste.
1.4 The key process of making structural glass assembly components
is reduced on the construction site, the construction period is
shortened, and the construction equipment is reduced.
1.5 Columns, beams, and glass plates are installed on site one by
one, easy to install and easy to adjust.
1.6 The construction is simple, the process flow is clear and easy
to understand, and the operator is easy to master, but it requires
higher professional skills and overall planning ability of the
manager.
2. Process flow
Construction preparation → measurement and setting out → embedded
parts processing → connection angle installation → column
installation → beam installation → structural glass assembly
assembly production and installation → cleaning inspection →
completion acceptance
3. Key points of construction operation
3.1 Construction preparation
3.1.1 Material preparation: According to the drawings and
engineering conditions, prepare a detailed material ordering and
supply plan.
3.1.2 Construction machinery: inspect the machinery used to ensure
its good performance.
3.1.3 Personnel preparation: Provide technical training and
confession to skilled workers.
3.1.4 Technical preparation: Be familiar with the drawings, and
prepare the tables for the relevant atlases, quality acceptance
standards and internal business data.
Performance Parameter | ||
Performance | EU-STD | GB/T7106 GB/T8484 |
Air Tightness | Class4 | Class8 |
Water Tightness | E1500 | Class6 |
Wind Resistance | C5 | Class9 |
Insulating Properties | K 1.45W/㎡·K | Class8 |
Sound Insulation | Rw=dB39 Glazing 5+12A+5+12A+5 |
Our Certification:
Performance Parameter | ||
Performance | EU-STD | GB/T7106 GB/T8484 |
Air Tightness | Class4 | Class8 |
Water Tightness | E1500 | Class6 |
Wind Resistance | C5 | Class9 |
Insulating Properties | K 1.45W/㎡·K | Class8 |
Sound Insulation | Rw=dB39 Glazing 5+12A+5+12A+5 |