FTP Cat 6A Cable, Cat 6A Network Cable, 23AWG BC, PVC Jacket

Brand Name:TC
Model Number:U/FTP-11-6A-4P-V1
Minimum Order Quantity:50 Boxes
Payment Terms:Western Union, T/T, L/C, MoneyGram
Place of Origin:China
Price:Negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Guangxi China
Address: No.618, Guangxing Rd, Songjiang District, Shanghai, P.R. China
Supplier`s last login times: within 15 hours
Product Details Company Profile
Product Details

Cat 6A Cable, Cat 6A Network Cable, Cat 6A Ethernet Cable, FTP Cat 6A Cable​ Application


It can be applied in horizontal cabling, as the portion of a telecommunications cabling system that extends from the work area telecommunications outlet to the patch panels in the distribution room, and in residential cabling that extends from the user telecommunications outlet to the patch panels.


TC's U/FTP-11 series, indoor Cat 6A shielded cabling system, has test frequency up to 600MHZ, higher than other Cat 6A cables with industry standard of 500MHz, especially useful for connecting servers, switches, patch panels, and other devices in the data center, as well as high bandwidth structured cabling system.


In the meantime, it supports Power Over Ethernet (POE/POE+).


Product Features


TC's Cat 6, 23 AWG, U/FTP shielded indoor cable adopts the excellent aluminum foil shield for each pair, optimized to greatly enhance technical indicators, including Attenuation, NEXT, and ANEXT, which exceed the parameters specified in GB/T 18015.5 (IEC 61156-5) standards.


It is especially useful in some harsh electromagnetic environments where high-speed and stable cable transmission is required.


At the same time, it acts on the requirements for high transmission in data center, and structured structured cabling in new buildings.


Application Standards


GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2


Technical Details


Transmission PerformanceCat.6ATC
Frequency (MHz)4100250300450500600
IL Attenuation (dB/100M)3.53.88.411.217.819.423.1
Near End Crosstalk Attenuation (NEXT, dB)101.1104.7105.3103.2110.495.696.6
NEXT Power and PS NEXT (dB)98.299.3100.399.1102.893.292.6
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB)95.891.58784.176.471.672.6
ACR-F Power and PS ACR-F (dB)91.488.185.486.376.969.167.9
Return Loss (RL, dB)40.941.337.93530.722.719.7

Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.

Physical Specifications
Conductor Size (nominal value)
4×2×0.57 (AWG23)
Outer Diameter of Cable (nominal
value)
7.5mm
Weight (305m, with package,
nominal value)
21kg

Electrical Properties
DC resistance (20℃ )
93.8Ω/km
Earth Capacity≦ 5.6 nF/100m (@1kHz)
100MHz Characteristic Impedance
100Ω±15Ω
Transverse Conversion Loss (TCL)
≥ 55dB-20×lgf (100-2000MHz)
Delay Skew25ns/100m
NVP
69%
Power Over Ethernet (POE)Enhanced Power Over Ethernet under IEEE 802.3at

Mechanical Properties
Minimum Bend Radius (dynamic)
30mm
Minimum Bend Radius (static)
60mm
Maximum Installation Tension100N
Anti-Extrusion Capacity1000N/10cm
Anti-Shock Capacity≥ 10 times
Installation Temperature Range-0℃ ~+40℃
Working Temperature Range-20℃ ~+75℃

Flammability (PVC)
PVC Flame Resistance
GB/T 18380.12 (IEC 60332-1-2)
Fire Rating CM
UL 1581/ UL 1666

Flammability (LSZH)
Flame Resistance (of single wire)GB/T 18380.12 (IEC 60332-1-2)
Flame Resistance (of bunched wires)GB/T 18380.35 (IEC 60332-3-24)
Smoke DensityGB/T 17651 (IEC 61034-1/-2)
Hazardous Halogen GasGB/T 17650.1/.2 (IEC 60754-1/-2)