CE certified AC220V Residual Current Protection Relay ASJ10-LD1C&LD1A

Brand Name:Acrel
Certification:CE
Model Number:ASJ10-LD1C&LD1A
Minimum Order Quantity:1 pcs
Delivery Time:3 days
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Address: No. 9 Xincheng Road,Chengjiang Street, Jiangyin City, Jiangsu Province,China
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

ASJ Series of action relay of after-current, low-voltage circuit break or low-voltage contactor can be made up for combined after-current production device, which is mainly applied for the TT and TN system distributing circuit with the alternating current 50/60Hz, the rated voltage 400V or below. ASJ Series of action relay of after-current is applied in the earth fault protection for the electric circuit, so as to prevent the equipment damage and the fire accident of electric equipment caused by the ground fault current, moreover, it also can provide indirect contact protection against the electric shock risk.


Technical Parameter


technical parameterASJ10-LD1CASJ10-LD1A
InputRated residual action current I△n0.03,0.1,0.3,0.5(A)

0.03,0.05,0.1,0.3,0.5,1,3,5,10,

30(A)

Non-driving time of limitation △t0.1,0.5(s)

0,0.06,0.1,0.2,0.3,0.5,0.8,1,4,

10(s

Rated residual non-action current I△no50%I△n50%I△n
performance characteristicssimple sinusoidal alternating currentsimple sinusoidal alternating current and pulsating direct current
frequency50Hz/60Hz50Hz/60Hz
action error-20% ~ -10%I△n
outputoutput modeone is the normal closing and the other is for the transformationone is the normal closing or opening, and the other is for the transformation
contact capacity

5A 250VAC 5A

30VDC

AL1:8A 250VAC 5A 30VDC AL2:6A 250VAC 5A 30VDC
reset modethe on-the-spot one and the long-distance one,the on-the-spot one, the long-distance one and the automatic one
power supplyvoltage range

AC110V,AC220V(permissible

error±10%)

AC110V,AC220V,DC85-270V

(permissible error±10%)

power dissipation≤5W
power frequency withstand voltageThe effective value of alternating current between the power supply, input and output: 2kV/1min
under the normal operationtemperature

operating temperature: -20℃ ~ +55℃

storage temperature: -30℃ ~ +70℃

humidity≤95%RH, with moisture condensation, and corrosive gas place
height above sea level≤2000m
class of pollutionGrade three
installation categoryType Ⅲ

Residual Current CT

ShapeTypeRated CurrentRatioAccuracyBurdenOverload ratio
L-4516-100A5/5mA110010
L-80100-250A
L-100250-400A
L-150400-800A
L-200800-1500A
L-80*50II16-200A5/5mA0.558
L-100*50II16-100A
L-130*50II100-200A
L-150*130II100-300A
L-180II100-200A
L-200*50II250-400A
L-260-100II450-800A

Writing

Typical Connection

Application

Solutions



China CE certified AC220V Residual Current Protection Relay ASJ10-LD1C&LD1A supplier

CE certified AC220V Residual Current Protection Relay ASJ10-LD1C&LD1A

Inquiry Cart 0