Acrel DIN Rail Type Multi Circuit Energy Meter 65Hz Data Center Monitor

Brand Name:Acrel
Certification:CE
Model Number:AMC16Z-FAK48
Minimum Order Quantity:1 Pieces
Delivery Time:2-3 days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Address: No. 9 Xincheng Road,Chengjiang Street, Jiangyin City, Jiangsu Province,China
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

General


With the rapid development of data center, the energy consumption problems about the data center have become increasingly serious, and energy management and the design of power supply and distribution have become hot problems; efficient and reliable power distribution system scheme for data center is an effective method to improve the power utilization efficiency of the data center and reduce the energy consumption of equipment. In order to achieve the energy conservation of data center, firstly it is necessary to accurately monitor each electricity load, but there are many loading circuits in the data center, and the traditional measuring instruments are incapable of satisfying the requirements for cost, volume, installation, construction and the like; hence, it is necessary to apply multi-circuit monitoring device applicable to the centralized monitoring requirements of data center.
AMC16 series multi-circuit monitoring device of Acrel Company is a measuring device designed
specifically for the power supply management of server in the data center. Such device is small and exquisite in design, capable of centralized monitoring on various electric parameters and on-off states of dozens of circuits, including incoming line circuit and outgoing line circuit, and it achieves the highly integration of monitoring circuits in volume.


Technical parameter


Technical parametersAMC16Z-FAK24AMC16Z-FAK48
Measurement parametersVoltage, current, frequency, active power, reactive power, power factor, active
power, reactive power, switching state
2-31 times harmonics
Bus VoltageRated220VAC
Measurement±20%
OverloadInstantaneous voltage 2 times/second
CurrentRated50mA
outgoing line loopRange0.125~60mA
OverloadDuration 1.2 times, instantaneous 10 times/second
Input frequency45~60Hz
Measurement accuracyOutgoing lineVoltage/current/active power/active energy level 0.5, reactive power/reactive energy level 1
Auxiliary power supplyPower supply by AMC16Z-ZA
Environment
TemperatureWorking:-15℃~55℃ Storage:-25℃~70℃
HumidityRelative humidity
Altitude
≤2500m
CommunicationRS485/Modbus-RTU
Installation method
DIN35mm Guide rail or bottom plate mounting
IP gradeIP20