DTSD1352 Three Phase Multi-Function Energy Meter


General


DTSD1352 power analyzer specializes in measuring the data of all kinds of AC networks. It can be used for local display, or it is connected with the control equipment in measuring and controlling system. They comply EN 61326:2006 and EN 61010-1:2001.

They are a kind of programmable analyzer. With the 2 key on the front, we can choose to read the data that we need. They can be equipped RS-485 communication Modbus-RTU.
They are a kind of analyzer with excellent cost performance, since they regroup the functions of traditional electric transmitter and digital meters. Therefore they are widely being used in kinds of control system, SCADA system and power management system.


Features


● AC 3×220/380V,3×380V,3×57.7/100V,3×100V
● 3×1(6)A,3×10(80)A
● U,I,P,Q,S,PF,kWh,kvarh
● RS485(MODBUS-RTU)
● LCD display
● Frozen data
● 2-31st Harmonics
● Alarm
● kWh Class 0.5S,kVarh Class 2

Technical parameters


Specification3 phase 3 wires, 3 phase 4 wires
VoltageReference voltage3×100V, 3×380V,3×57.7/100V, 3×220/380V
Consumption<10VA(Single phase)
Impedance>2MΩ
Accuracy classError±0.2%
CurrentInput current3×1(6)A,3×1(6)A(Outlay transformer),3×10(80)A,3×10(100)A(Outlay transformer)
Consumption<1VA(Single phase rated current)
Accuracy classError±0.2%
PowerActive, reactive, apparent power, error±0.5℅
Frequency45~65Hz, Error±0.2%
Temperature-40℃~99℃
EnergyActive energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2)
Clock≤0.5s/d
Energy pulse output1 active optocoupler output, 1 reactive optocoupler output
Switching output1 Switching output, Maximum allowed voltage: DC/AC 220V
Switching input1 optocoupler input,Maximum allowed voltage: DC/AC 220V
Width of pulse80±20ms
Pulse constant6400imp/kWh,400imp/kWh(Correspond with the basic current)
Interface and communicationRS485:Modbus RTU
Range of communication addressModbus RTU:1~ 247;
Baud rate1200bps~19200bps
Relative temperature-25℃~+55℃
Relative humidity≤95℅(No condensation)