Make Glaucoma Diagnosis Easier Higher Stability Projection
Perimeter
Projection Perimeter Patient Instructions for Static Testing "If
you want to rest, hold down on the button (demonstrate to patient).
The test will resume whenyou release the button. We test one eye at
a time. Blink normally so your eye does not get dry. Agood time to
blink is whenever you push the response button. When your test is
over, you will heartwo beeps. You may sit back at that time."
Technical Specification of Projection Perimeter
Specification | ||
Testing scope | 90° | |
Testing distance | 30CM | |
Background light | white31.5asb,yellow315asb | |
Visual target | 0.08asb---10000asb(0-51DB) | |
Target size | GoldmannⅠ, II ,III,IV,V | |
Visual target stimulation time | 200ms | |
Visual target interval time | Standard and custom | |
Threshold policy | Macula,10-2,24-2,30-2,60-4,nasal side | |
Upper threshold policy | C-40,C-64,C-76,FF-81,FF-120,FF-135…… | |
Special detection strategy | Esterman monocular,Esterman binocular,upper36°screening,blind point testing | |
Yellow-blue testing | Standard 440nm blue visual target + 315asb OG530yellow background brightness | |
Visual target | Red ,blue | |
Dynamic policy | Standard dynamic,blind dynamic,dark spot dynamic ,straight line dynamic | |
Custom policy | Static custom dynamic custom | |
Pupil size measurement | Auto | |
Fixation monitoring | Physiological blind spot monitoring,eye position monitoring,eye position moving alarm,eye tracking curve | |
Environment light testing | Auto | |
Analysis software | reliability analysis , single report, triple report, GHT glaucoma semi vision report, GPA glaucoma developing analysis, VFI analysis, Blue-yellow analysis | |
System | Win7 above | |
Others | ||
Size | 412mm(length)* 497mm(width)* 513mm(height) | |
Wight | 17kg | |
Power | 100-240V HZ:50-60Hz |
Feature of Projection Perimeter
* Rigorous implementation of Goldman international standard.
* Accurate and elaborate database of normal population of all age
groups, recognition of more subtle early visual field defects.
* GHT glaucoma semi vision analysis, make glaucoma diagnosis
easier.
* GPA glaucoma progression analysis upgrade, slight glaucoma
development is obvious strategy, 30° range visual field inspection only takes 3 minutes.
* Projection Perimeter Simple one-stop modular software design, equipment operation
learning only 2 minutes
*.Zeiss humphrey 860 same function
Since Projection Perimeter is a precision instrument ,always use and keep it in a normally
conttolled living Environment, within a temperature range of
10-40℃, humidity levels between 40%-80% and an atmospheric pressure
range of 760hPa-1060hPa. The instrument should also be placed away
from direct sunlight.
To ensure smooth operation, install the instrument on a level
floor free of vibrations.
Also, do not place anything on the instrument.
Connect all cables properly before using.
Use the power at rated voltage.
When not in use, switch off the power source and apply the rubber
cap and dust cover.
Company Introduction
Focusing on the two major public health problems of adolescent
myopia and elderly ophthalmology, our company researches new
diagnostic and treatment equipment for ophthalmology, develops
low-cost applicable technology products, realizes
industrialization, reduces the cost of social medical and health
system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development
concept.We have a strong technical force, has been awarded 11 patents, and
obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect
after-sales service system to provide medical equipment with the
highest cost performance and meticulous service.