Product Details
Disposable Use Of Human Arterial Blood Samples Collector(S-3)
Structure composition
The disposable human arterial blood sample collector (hereinafter
referred to as the collector) S-3 is composed of a sample
container, a pull rod, a piston, a piston breather valve, a seal, a
blood sampling needle, a needle sheath, and a cubic plastic block.
D-3 is composed of sample container, pull rod, piston, piston
breather valve, seal, blood collection needle, needle sheath, and
button sheath.
Objective
- Taking arterial blood for blood gas analysis is the best way to
objectively reflect the nature and degree of respiratory failure,
and to judge whether there is hypoxia and carbon dioxide retention
- Guide the adjustment of various parameters of oxygen therapy and
mechanical ventilation
- Arterial administration in emergency
Scope of application
Suitable for the collection and storage of arterial blood samples,
and the blood gas analysis of the collected blood samples
Storage of specimens
- The blood contains active respirable cells (white blood cells,
reticulocytes), which continue to consume oxygen to produce CO 2
after sampling. Generally, arterial blood samples are stored in
vitro at 37°C. PaCO 2 increases by 1mmHg every 10 minutes and pH
decreases by 0.01. Therefore, the blood should be sent for
examination immediately after the blood is drawn. Generally, the
time from the collection of the specimen to the completion of the
determination should not exceed 30 minutes.
- In case of special circumstances that cannot be measured
immediately, it should be placed in a container containing ice
water or in a refrigerator, but the storage time should not exceed
2 hours. Place it at room temperature for a few minutes before the
measurement, because every 1°C drop in temperature can increase the
pH by 0.014, which also affects PaO2 and PaCO2.
usage method
- Select the human artery and take out the disposable human arterial
blood sample collector;
- Pull the lever to the pre-collection volume position;
- Remove the needle sheath, puncture the artery, arterial blood will
gush out naturally;
- When the arterial blood reaches the preset position, the piston
vent valve is closed when wet, and the blood sampling device is
pulled out;
- Activate the safety device (buckle the button sheath or insert the
needle into the cubic plastic block to prevent accidental
stabbing), and remove the needle;
- Screw on the seal to seal it and leave it for testing.
contraindication
- Anticoagulant therapy;
- Patients with severe peripheral atherosclerosis;
- Patients with coagulopathy;
- Patients with a history of vasospasm after puncture;
- Do not sample from areas with inflammation, purulent infection,
induration, scars, and skin diseases.
Precautions, warnings and suggestive instructions
- One-time use, destroy after use;
- If the packaging container has been opened or damaged, it is
prohibited to use the contents;
- The use of the product must comply with the requirements of the
relevant operating specifications and relevant regulations of the
medical department;
- During the use of the product, it should be carried out slowly to
avoid excessive force, which may cause pain to the patient;
- After use, discard it as infected waste.
warning
- When using the product, medical personnel should collect blood
samples, and handle blood samples and blood collection equipment
carefully. Please wear qualified rubber gloves to avoid direct
blood contact. During the whole blood collection process, please
adopt aseptic technique to prevent infection of the blood
collection site.
- If there are bubbles in the collector, remove them immediately and
seal the sample container with a seal.
- Turn the collector upside down several times, and then roll it back
and forth in the palm of your hand several times to ensure that the
blood sample is well mixed.
- Avoid storing blood samples, or minimize storage time. If it is not
possible to test immediately, please store it in a refrigerator at
4°C, and test the blood sample within 30 minutes after collection
Company profile
Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise
engaged in the research and development, production and operation
of in vitro diagnostic products. The in vitro diagnostic products
developed by the company cover POCT series, microbial series,
biochemical series and immune series reagents and supporting
instruments.
The company has always adhered to the core concept of "fast and
accurate, living up to life", committed to providing society with
excellent products and services, and contributing to the cause of
human health.
Company Profile
Zhongxiu Science And Technology Co.,Ltd., founded in 2016, is
located in Dingluan Industrial Zone, Changyuan City, Henan
Province. The company covers an area of about 100 acres and the
initial investment is about 200 million yuan. The company has a
scientific and complete management system, a purification workshop
of national standards, and a fully functional inspection center. On
this basis, the company will continue to invest in research and
development, accumulate technical strength, update manufacturing
equipment, improve production technology, improve inspection
technology, improve product quality, and provide customers with
safe and effective in vitro diagnostic products.
Zhongxiu Science And Technology Co., Ltd. is a high-tech enterprise
engaged in the research and development, production and operation
of in vitro diagnostic products. The in vitro diagnostic products
developed by the company cover POCT series, immune series,
microbial series and other reagents and supporting instruments.
The company has always adhered to the core concept of “fast and
accurate, living up to life”, committed to providing society with
excellent products and services, and contributing to the cause of
human health.