230V DIP Gas Discharge Tube Gas Plasma Arrestors Non Radioactive

Brand Name:TIAN RUI
Certification:ROHS and REACH
Model Number:2RK-5 Series
Minimum Order Quantity:1000PCS
Delivery Time:5-7 days
Payment Terms:D/P,T/T,Paypal,Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: Building C, Xinmeijia Science and Technology Park, Chashan
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details
2RK-5 Series 2R230 2R250 2R300 2R350 DIP Original Gas Plasma Arrestors Surge Suppressor Gas Discharge Tube
Description
The principle of gas discharge is used not only for overvoltage protection but also in switching applications. Unlike surge arresters, switching spark gaps are active components that work reliably even after igniting hundreds of thousands of times.
2RK-5 series Switching Spark Gaps(SSG) can be used in all applications where high voltage pulses are generated, for example to ignite modern high-pressure gas discharge lamps such as xenon lamps in automotive headlights. Ignition performance is determined to a large degree by the properties of the switching component. An extremely fast switch is called for, which operates virtually without loss and with high insulation resistance in the non-conducting state. It should also be as compact as possible, rugged, highly reliable, and capable of operating over a wide temperature range.

Features
 Extremely long life time

 Stable performance over life

 Insensitive performance against variations in temperature

 Low switching losses

 Very short breakdown time

 High reliability by robust design

 Lead-free compliant

 RoHS and REACH compliant

 Non-Radioactive
Applications
 Igniters for architectural and automotive Xenon discharge lamps

 Electronic igniters for gas heating and gas domestic appliances, e.g., cookers

 Ignition of ultra-high pressure gas discharge lamps for data and video projectors
Part Number Code
Electrical Characteristics
Part NumberDIP2R230TK-5
2R230SK-5
2R250TK-5
2R250SK-5
2R300TK-5
2R300SK-5
2R350TK-5
2R350SK-5
SMD
Initial Values
Static Breakdown Voltage VS @100V/S 1)
First ignition Value after 24 hours in darkness Following Ignition Values
<275 V 207~253 V<300 V 225~275 V<360 V 270~330 V<420 V 315~385 V
Electrical Life Time
Breakdown Voltage VB 2)
First ignition Value after 24 hours in darkness Following Ignition Values
Switching Operations @ +25°C Breakdown Time
Maximum Switching Frequency
<285 V<310 V<370 V<435 V
196~265 V
105
215~290 V
105
255~350 V
105
300~405 V
105
<50 ns<50 ns<50 ns<50 ns
100 Hz100 Hz200 Hz200 Hz
Test Circuit Parameters
Open Circuit Voltage V0230 VAC350 V400 V450 V
Loading Resistance R15 KΩ10 KΩ10 KΩ10 KΩ
Discharge Capacitance C2.2 µF680 nF680 nF680 nF
Inductance L10 µH0.5 µH0.5 µH0.5 µH
Discharge Peak Current IP~300 A~500 A~500 A~500 A
Part NumberDIP2R380TK-5 3)
2R380SK-5 3)
2R400TK-5
2R400SK-5
2R450TK-5
2R450SK-5
2R470TK-5
2R470SK-5
SMD
Initial Values
Static Breakdown Voltage VS @100V/S 1)
First ignition Value after 24 hours in darkness Following Ignition Values
<460 V 350~420 V<480 V 360~440 V<540 V 405~495 V<560 V 423~517 V
Electrical Life Time
Breakdown Voltage VB 2)
First ignition Value after 24 hours in darkness Following Ignition Values
Switching Operations @ +25°C Breakdown Time
Maximum Switching Frequency
<460 V<500 V<560 V<585V
330~440 V
105
340~460 V
105
385~515 V
105
400~540 V
105
<50 ns<50 ns<50 ns<50 ns
200 Hz200 Hz200 Hz200 Hz
Test Circuit Parameters
Open Circuit Voltage V0500 V520 V580 V600 V
Loading Resistance R10 KΩ10 KΩ10 KΩ10 KΩ
Discharge Capacitance C680 nF680 nF680 nF680 nF
Inductance L0.5 µH0.5 µH0.5 µH0.5 µH
Discharge Peak Current IP~500 A~500 A~500 A~500 A
Part NumberDIP2R500TK-5
2R500SK-5
2R550TK-5 4)
2R550SK-5 4)
2R600TK-5
2R600SK-5
SMD
Initial Values
Static Breakdown Voltage VS @100V/S 1)
First ignition Value after 24 hours in darkness Following Ignition Values
<600 V 450~550 V<680 V 510~630 V<720 V 540~660 V
Electrical Life Time
Breakdown Voltage VB 2)
First ignition Value after 24 hours in darkness Following Ignition Values
Switching Operations @ +25°C Breakdown Time
Maximum Switching Frequency
<625 V 425~575 V
105
<50 ns
200 Hz
<710 V 485~655 V
105
<50 ns
200 Hz
<750 V 510~690 V
105
<50 ns
200 Hz
Test Circuit Parameters Open Circuit Voltage V0 Loading Resistance R Discharge Capacitance C Inductance L
Discharge Peak Current IP
630 V
13 KΩ
470 nF
0.1 µH
~600 A
720 V
13 KΩ
470 nF
0.1 µH
~600 A
750 V
13 KΩ
470 nF
0.1 µH
~600 A
Insulation Resistance @100 V>108 Ω
Capacitance @1MHz<1 pF
WeightDIP ~0.82g SMD ~0.55g
Operation and storage temperature-40~+125°C
Surface treatmentDIP -Nickel Plated SMD -Matte-tin plated

1) At delivery AQL 0.65 level II, DIN ISO 2859


2) Fig. 1


3) 350 Marking


4) 600 Marking


Test Circuit Fig. 1


Dimensions (Unit: mm/inch)


DIP Series (2RxxxTK-5)

SMD Series (2RxxxSK-5)

Packaging Information (Unit: mm/inch)

Packaging Quantity

100 PCS per Plastic Tray
5 Plastic Trays per inner box
500 PCS per inner box

Axial Packaging (Tape & Reel)

SMD Packaging (Tape & Reel)

Packaging Quantity

1,000 PCS per reel (13”)
3 reels per inner box
3,000 PCS per inner box

Basic Application Circuit

Soldering Parameters - Wave soldering (Thru-Hole Devices)

Wave Soldering ConditionPb-Free assembly
PreheatTemperature Min100°C
Temperature Max150°C
Time (Min to Max)60-180 Seconds
Solder Pot Temperature280°C Max
Solder Dwell Time2-5 Seconds

Soldering Parameters - Reflow Soldering (Surface Mount Devices)

Reflow ConditionPb - Free assembly
Preheat-Temperature Min (Ts(min))150°C
-Temperature Max (Ts(max))200°C
- Time (min to max) (ts)60 -180 Seconds
Average ramp up rate ( Liquids Temp TL) to peak3°C/second max
TS(max) to TL - Ramp-up Rate5°C/second max
Reflow- Temperature (TL) (Liquids)217°C
- Time (min to max) (ts)60 -150 Seconds
Peak Temperature (TP)260 +0/-5°C
Time within 5°C of actual peak Temperature (tp)10 - 30 Seconds
Ramp-down Rate6°C/second max
Time 25°C to peak Temperature (TP)8 minutes Max
Do not exceed260°C


China 230V DIP Gas Discharge Tube Gas Plasma Arrestors Non Radioactive supplier

230V DIP Gas Discharge Tube Gas Plasma Arrestors Non Radioactive

Inquiry Cart 0