2RD-8S Gas Discharge Tubes Impulse Current Capability 2R 20kA GDT Lightning Arrester Surge Protection

Brand Name:TIAN RUI
Certification:ROHS REACH
Model Number:2RD-8S
Minimum Order Quantity:1000PCS
Delivery Time:5-7 days
Payment Terms:D/P,T/T,Paypal,Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: Building C, Xinmeijia Science and Technology Park, Chashan
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

2RD-8S Gas Discharge Tubes Impulse Current Capability 2R 20kA GDT Lightning Arrester Surge Protection


Description of 2RD-8S Gas Discharge Tubes 2R 20kA GDT


Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes. The ceramic envelope and with nickel connectors allow for high loads. 2RD-8S Gas Discharge Tubes (GDT) series has a surge rating of 20kA, 8/20μs.Offered in a Squared Surface Mount package, which helps to make pick and place on PCB process easier.


This GDT series is perfectly suited for broadband equipment applications. The GDT’s low off-state capacitance is compatible with high bandwidth applications and this capacitance loading value does not vary if the voltage across the GDT changes.


2RD-8S Gas Discharge Tube (GDT) series are specifically designed for protection of electrical, multimedia, and communication equipment against over voltage transients in surface mount assembly applications.



Features of 2RD-8S Gas Discharge Tubes 2R 20kA GDT


• Excellent response to fast rising transients
• Stable breakdown voltage
• GHz working frequency
• 8/20μs Impulse current capability: 20KA
• Non-Radioactive
• Ultra Low capacitance (<1.5pF)
•l Lead-free compliant
•l RoHS and REACH compliant
•l Size: 8.3mm*6mm
• Storage and operational temperature: -40~+90°C


Applications of 2RD-8S Gas Discharge Tubes 2R 20kA GDT


• MDF modules
• xDSL equipment
• RF systems
• Antenna
• Base stations
• Repeaters, Modems
• Telephone Interface, Line cards
• Data communication equipment
• Line test equipment
• Power supplies
• Surge protectors, Alarm systems


Part NumberDC
Spark-over Voltage 1) 2) @100V/S
Impulse Spark-over VoltageInsulation Resistance
3)
Capacitance @1MHzLife Ratings
Impulse Discharge Current @8/20μSImpulse Voltage @1.2/50μSImpulse Discharge Current @10/350μSAC
Discharge Current @50Hz 1S
Impulse Life @10/1000μS 200A
100V/μS1KV/μS
MaxMaxMinMaxNominal
±5 times
Max 1 timeNominal
±5 times
1 timeNominal 5 timesMin
VVVpFKAKAKVKAATimes
2R075D-8S75±20%50060011.5202540520300
2R090D-8S90±20%50060011.5202540520300
2R150D-8S150±20%50060011.5202540520300
2R230D-8S230±20%60070011.5202540520300
2R250D-8S250±20%60070011.5202540520300
2R300D-8S300±20%75085011.5202540520300
2R350D-8S350±20%80090011.5202540520300
2R400D-8S400±20%85095011.5202540520300
2R420D-8S420±20%85095011.5202540520300
2R470D-8S470±20%900100011.5202540520300
2R600D-8S600±20%1000120011.5202540520300
2R800D-8S800±20%1300140011.5202540520300
2R1000D-8S1000±20%1500160011.5202540520300
Glow Voltage at 10mA ~60V
Arc Voltage at 1A............................................................................... ~10V
Glow to Arc transition Current ~1.0A
Weight…………………………………………………………………...... ~1.38g
Operation and storage temperature……………………………………. -40~+90°C
Climatic category (IEC 60068-1)……………………………………….. 40/90/21

SymbolMillimetersInches
A8.3±0.20.327±0.008
B8.3±0.20.327±0.008
C6±0.30.236±0.012
DФ8±0.2Ф0.315±0.008
EФ9.3±0.2Ф0.366±0.008
F0.5±0.10.020±0.004
X1.20.047
X15.80.228
Y9.00.354

SymbolMillimetersInches
W16±0.30.630±0.012
A08.3±0.10.327±0.004
B06.3±0.10.248±0.004
K08.4±0.10.331±0.004
P12±0.10.472±0.004
F7.5±0.10.295±0.004
E1.75±0.10.069±0.004
D1.5+0.1/-0.00.059+0.004/-0.0
P04±0.10.157±0.004
P22±0.10.079±0.004
T0.5±0.10.020±0.004
D013.3±0.150.524±0.006
D1330±212.992±0.079
D2100+1/-23.937+0.039/-0.079
W116.5±0.40.65±0.016

Soldering Parameters - Reflow Soldering (Surface Mount Devices)


Reflow ConditionPb - Free assembly
Pre Heat-Temperature Min (Ts(min))150°C
-Temperature Max (Ts(max))200°C
- Time (min to max) (ts)60 -180 Seconds
Average ramp up rate ( Liquids Temp TL) to peak3°C/second max
TS(max) to TL - Ramp-up Rate5°C/second max
Reflow- Temperature (TL) (Liquids)217°C
- Time (min to max) (ts)60 -150 Seconds
Peak Temperature (TP)260 +0/-5°C
Time within 5°C of actual peak Temperature (tp)10 - 30 Seconds
Ramp-down Rate6°C/second max
Time 25°C to peak Temperature (TP)8 minutes Max
Do not exceed260°C
China 2RD-8S Gas Discharge Tubes Impulse Current Capability 2R 20kA GDT Lightning Arrester Surge Protection supplier

2RD-8S Gas Discharge Tubes Impulse Current Capability 2R 20kA GDT Lightning Arrester Surge Protection

Inquiry Cart 0