Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable

Brand Name:TIAN RUI
Certification:ROHS
Model Number:CWFM0103FC1-xxxM113X
Minimum Order Quantity:1000PCS
Delivery Time:5-7 work days
Payment Terms:T/T, Paypal, Mastercard, Wetern Union, Alipay, etc
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: Building C, Xinmeijia Science and Technology Park, Chashan
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable


Description Of Underfloor Heating Thermistor Temperature Sensor


The Probe and Sensor are used to control temperature where moisture would be a problem i.e. in wet room or bathroom. It can also control floor temperature where overheating would cause damage.

The temperature of an underfloor heating system is controlled via a thermostat that reads the temperature of the room through sensors. With underfloor heating, it’s common for there to be two types of sensor installed, the usual air sensor (in the thermostat itself) as well as an underfloor heating probe, or floor sensor.




Features Of Underfloor Heating Thermistor Temperature Sensor


* Works with a wide range of different thermostats
* Please check the resistance values of your current sensor against the table below for compatibility
* Cable has high rigidity, allowing it to be easily passed through existing flexible conduit
* Suitable for use in wet areas. IP68 Rated (When installed according to manufacturers instructions)
* No polarity, simply connect the two wires either way round to the sensor outlet on the thermostat
* Rubber thermoplastic protective housing for NTC sensor

* The cable measures about 3 meters in length.
* Rubber thermoplastic protective housing for NTC sensor.
* This sensor has a resistance of 10K Ohms @ 25℃.
* Mainly used for underfloor heating thermostat to measure floor temperature, also suitable for monitoring piping water temperature, indoor temperature and outdoor temperature.
* Easy to connect with underfloor heating thermostat, the sensor probe can be stick to electrothermal film.


Dimension Of Underfloor Heating Thermistor Temperature Sensor


Unit:mm

Dimension (unit:mm)
ABCDL
6.52025±53±1As required

Material Information Of Underfloor Heating Thermistor Temperature Sensor


NOMaterial NameMaterial and Specifications
2-1.ElementR25=10KΩ±1% B25/50=3950K±1% DC
2-2.CoatingNTC encapsulated using PVC over-mold material (White)
2-3Cable features

UL2464-22AWG Tin plated copper cable with white PVC flat jacket wire 80℃ 300V


2-4.Wire endsTinned

Performances Of Underfloor Heating Thermistor Temperature Sensor


NOItemSignTest ConditionsMin.Nor.Max.Unit
4-1.Resistance at 25℃R25

Ta=25±0.05℃

PT≦0.1mw

9.910.010.1
4-2.B ValueB25/503910.539503989.5k
4-3.Dissipation factorσIn still airAbout 2mW/℃
4-4.Time responseτIn flowing waterAbout 15sec
4-5.Withstanding Voltage/1500VAC 2SecNo breakdownSec
4-6.Insulation Resistance500VDC≧100
4-7.Operating temp. range//-30/+105

Application Of Underfloor Heating Thermistor Temperature Sensor


1. Temperature measurement,
2. Sensing and control: White goods, Refrigerators, freezers, deep-freezers, coolers Ice cube makers
3. Floor heating system


How to Install an Underfloor Heating Thermistor Temperature Sensor


When installing a floor sensor, you should always follow the manufacturer’s instructions supplied however, there are some general rules that should be applied when installing any underfloor heating probe.
The probe should be placed equal distance between heating wires and should never cross a heating wire.
The probe can be installed either above or below your electric underfloor heating mat.
Areas in which the temperature may be affected such as near external doors or on heating pipes, should be avoided.


How to Test an Underfloor Heating Thermistor Temperature Sensor


During installation, the underfloor heating probe should be tested to ensure it is working correctly. This will be done by the installer. In order to do this, they will use a digital multimeter. A multimeter is an electronic measuring device that can usually measure voltage, resistance and current. In this case, your installer will be measuring resistance (ohms Ω).
To test if the underfloor heating sensor is working correctly, they will attach the multimeter probes to the floor sensor cable. At normal room temperature, the multimeter should read 10kΩ at 25°C. If this is the case your sensor cable is working correctly and the install can be completed.


China Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable supplier

Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable

Inquiry Cart 0