Temperature range: 60℃ ~180℃;
Temperature tolerance: ± 5℃;
All adhesive parts shall not displaced by 3.0kg
Temperature Code | Action Temperature (℃) ±5℃ | Reset Temperature (℃) ±15℃ | |||||||||||
HC06 050 | 50 | ≥35 | |||||||||||
HC06 055 | 55 | ≥35 | |||||||||||
HC06 060 | 60 | ≥35 | |||||||||||
HC06 065 | 65 | ≥35 | |||||||||||
HC06 070 | 70 | ≥35 | |||||||||||
HC06 075 | 75 | ≥35 | |||||||||||
HC06 080 | 80 | ≥35 | |||||||||||
HC06 085 | 85 | ≥35 | |||||||||||
HC06 090 | 90 | ≥35 | |||||||||||
HC06 095 | 95 | ≥35 | |||||||||||
HC06 100 | 100 | 67 | |||||||||||
HC06 105 | 105 | 70 | |||||||||||
HC06 110 | 110 | 72 | |||||||||||
HC06 115 | 115 | 75 | |||||||||||
HC06 120 | 120 | 78 | |||||||||||
HC06 125 | 125 | 82 | |||||||||||
HC06 130 | 130 | 85 | |||||||||||
HC06 135 | 135 | 90 | |||||||||||
HC06 140 | 140 | 93 | |||||||||||
HC06 145 | 145 | 95 | |||||||||||
HC06 150 | 150 | 100 | |||||||||||
HC06 155 | 155 | 102 | |||||||||||
HC06 160 | 160 | 105 | |||||||||||
HC06 165 | 165 | 110 | |||||||||||
HC06 170 | 170 | 115 | |||||||||||
HC06 175 | 175 | 118 | |||||||||||
HC06 180 | 180 | 120 |
Drawing of HC06 Thermostat Temperature Switch Button Motor Thermal Protector 10A 260C 250C 200C 180C 250V
Characteristic Description of HC06 Thermostat Temperature Switch Button Motor Thermal Protector 10A 260C 250C 200C 180C 250V
1. The product has ultra-thin volume, sensitive action and long
life;
2. With the dual protection function of overcurrent and temperature
sensing;
3. Use beryllium copper material with low resistance value to
withstand the requirements of normal circuit current;
4. The shell can be insulated and easy to install;
5. Electric leads can be selected according to customer needs;
6. The products strictly comply with the environmental protection
standards of the EU ROHS Directive and the REACH Directive.
Certification and Life Span of HC06 Thermostat Temperature Switch Button Motor Thermal Protector 10A 260C 250C 200C 180C 250V
1. ROHS
2. In the conditions of rated voltage, current and power factor
0.7, the product
can be normal on-off 2000 times operated due to external heat
source.
A,The action temperature change shall be within + / -5℃ of the
initial value;
B,Contact resistance shall be below 50mΩ(except for special wire or
nickel
sheet)
C,The electrical contact does not fuse or fall off;
Continue the experiment to 10000 times
Product Design and Working Principle of HC06 Thermostat Temperature Switch Button Motor Thermal Protector 10A 260C 250C 200C 180C 250V
The product has too high current, temperature sensing double protection function;
Current overload protection principle of HC06 Thermostat Temperature Switch Button Motor Thermal Protector 10A 260C 250C 200C 180C 250V
The current passes through the static contact terminal 1, and then
forms a circuit through the current plate and the static contact 2,
When the
electrical current exceeds the jump value set by the protector, the
protector will cut off the power supply within the set time, so
that the electrical
appliance is protected;
Temperature Protection Principle of HC06 Thermostat Temperature Switch Button Motor Thermal Protector 10A 260C 250C 200C 180C 250V
The current passes through the static contact terminal 1, and then
forms a circuit through the current plate and the static contact 2,
When the
the surrounding temperature is too high, the heat to the bimetal
plate to the corrected jump temperature makes the electrical
contact quickly
disconnected circuit, when the temperature drops to the reset
temperature, the bimetal plate reset and quickly close the
electrical contact connected circuit, and continue to cycle.