Neware 8 Channel Battery Cell Tester Echelon Utilization Capacity Test

Brand Name:Neware
Certification:CE
Model Number:CT-4008T-5V6A-S1
Minimum Order Quantity:1 Unit
Delivery Time:8 working days
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Shenzhen China
Address: 15/F, Tower 3, Excellence City, No.128, Zhongkang Rd., Shenzhen, CHINA 518049
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Neware 8 Channer Cell Tester Lithium Battery Echelon Utilization Capacity Tester


a . New technology and upgraded producing process make this idea come into reality . Of course , high C - Rate charge - Quick charge is another reason for higher current testers become more popular than before . For a 3000mAh cell battery , people want to charge it at 6000mA - 2C or even 9000mA - 3C current .


b . And in some labs , researchers are trying 10C or even higher C - Rate charge or discharge . In this situation , 5V12A is the very rising star for both battery manufactures and researchers .


c . The accuracy for current and voltage on these channels is 0.05 percent of FS . From the base system that provides the highest level of accuracy and time resolution , features can be added to allow the 5V6A test system to perform virtualy many type of test , with many type of products – cylindrical , pouch and coin cells , super – capacitors , etc , and chemistries .


d . To meet the various requirements adopted in advanced battery research , our equipments can automatically switch the current range in accordance with user settings to maintain consistent accuracy , and can be fitted with additional hardware to provide a number of optional features and capabilities .


e . Cylindrical batteries need to be clamped between the upper and down clamps of the equipment . By moving the position of the upper accessory accurately according to the scales on both sides , you can test different capacities of Cylinders Batteries .


Input Power425W
Channel FeaturesConstant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure
Channel Control ModeIndependent Control
VoltagePer Channel Voltage Range1.5V - 5V
Discharge Min Voltage1.5V
Accuracy0.05 percent of FS
Stability0.05 percent of FS
CurrentPer Channel Current RangeRange1 , 5mA - 1A Range2 , 1A - 6A Range3 , 6A - 12A
Accuracy0.05 percent of FS
Stability0.05 percent of FS
Data RecordingRecord ConditionMin Time - 100mS
Min Voltage - 10mV
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA
Record Frequency10Hz
PulsechargeCCC , CPC
DischargeCCD , CPD
Min Pulse Width500ms
Automated SwitchAutomated swith from charge to discharge for each pulse
End ConditionVoltage, Test Time
CycleLoop Measure Range65535 times
Max Steps Per Loop254
Nested LoopNested loop Function , Max Support 3 Layers
ProtectionSoftware ProtectionPower - down Data Protection
Off - line Testing Function
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time
IP protection levelProtection level IP20
A Means of Communication of Upper MachineTCP / IP Protocol
Data OutputEXCEL , TXT , Graph
Communication InterfaceEthernet Port

China Neware 8 Channel Battery Cell Tester Echelon Utilization Capacity Test supplier

Neware 8 Channel Battery Cell Tester Echelon Utilization Capacity Test

Inquiry Cart 0