Add to Cart
XB-660F Temp Pressure Flow Monitoring Instrument
The XB-660F temperature, pressure, flow, and humidity monitor comprises a pitot tube, thermal resistance, micro pressure difference / absolute pressure sensor group, back blowing unit, and signal control processor. It is an integrated flow rate, dynamic pressure, static pressure, and smoke temperature monitor specially developed for the high dust, high temperature, high humidity, and high corrosion environment of exhaust gas monitoring. It is applicable to the real-time continuous measurement of the flow rate, pressure, temperature, and flow of exhaust gas by the continuous exhaust gas monitoring system (CEMS). The pitot tube, pressure sensor, and temperature sensor are used to measure the dynamic pressure, static pressure, and temperature of the exhaust gas. These parameters are proportional to the measured exhaust gas flow rate, so the flow rate of the exhaust gas can be quantified.
Features:
* Originally imported sensor chips, to ensure the accuracy and service life of the instrument
* Debuggable probe rod, adjust the length of the probe rod by itself according to the need.
* Probe rod made of 316F, corrosion resistance.
* Increased humidity measurement, no need to purchase a separate humidity meter more cost-effective. simple installation and easy maintenance.
* Real-time online monitoring of humidity, temperature, static pressure, dynamic pressure, and flow rate real-time upload.
* Set with automatic zero calibration, the automatic blowback Pitot tube is not easy to clog long service life removable pressure module for more convenient maintenance.
* Positive and negative power protection modules can be used without worrying about reverse connection and burning the machine.
* Debuggable probe rod, adjust the length of the probe rod by itself according to the need.
* Probe rod made of 316F, corrosion resistance.
* Increased humidity measurement, no need to purchase a separate humidity meter more cost-effective. simple installation and easy maintenance.
* Real-time online monitoring of humidity, temperature, static pressure, dynamic pressure, and flow rate real-time upload.
* Set with automatic zero calibration, the automatic blowback Pitot tube is not easy to clog long service life removable pressure module for more convenient maintenance.
Temperature measurement method | TP100 thermistor |
Pressure measurement method | Micro differential pressure sensor |
External working temperature | Instrument: -20~300℃ |
Flow rate range | 0-40m/s |
Temperature range | 0-300℃ |
Pressure range | 2000Pa |
Flow rate measurement accuracy | ±2.5%FS |
Pressure measurement accuracy | ±2.5%FS |
Temperature measurement accuracy | ±2.5%FS |
Blowback gas | Instrument gas 0.3~0.8MPa |
Transmission protocol | Modbus protocol |
Pitot tube | 316F stainless steel material |
Display mode | two-colour LCD display, LCD display resolution 3 or 4 decimals,
software for setting, no backlight since 30 minutes (can be set), current loss 4mA (no backlight) |
Communication mode | RS485,4-20MA communication mode |
Sampling mode | in-line, in-situ |
Working power | AC220V±5% 50Hz |
Main board power consumption | standby ≤ 3 W, back-blowing, zero calibration ≤ 25 W |
Probe length | conventional 0.5m, 1.0m, customizable (<1.8m) scalable
adjustment |
Service life | meter > 24 months, sensor > 20 months (used under normal
conditions) |
Installation | plug-in, DN65 standard flange installation |