Add to Cart
MS600-VOC Portable Multiple Gas Detector
MS600 Series Portable composite gas detector can be used in mobile rapid and accurate detection of a variety of gas concentrations and measurement of environmental temperature and humidity.
*Built-in humidity dust filter, preliminary treatment of the
detection gas, so as to protect the equipment.
*Multiple alarm modes, and multi-directional and three-dimensional
indication alarm states.
Multiple alarm mode settings: low alarm, high alarm, interval
alarm, and weighted average alarm.
*Zero-point automatic tracking; long-term use will not be affected
by the zero drift.
*Multi-level calibration for target points, can ensure the
linearity and accuracy of the measurements.
*Log recording Record the calibration logs, repair logs, failure
history, failure countermeasure solutions, sensor service life due
reminder, and function of reminder for the time of the next
concentration calibration.
*Data recovery function.
*Detection principles include electrochemical, catalytic combustion, infrared, thermal
conductivity, PID photoionization, and so on. Depending on the type of gas, range, field environment, and user
demand.
*Mis-operation recognition function: automatic recognition and
prevention of the concentration calibration misoperation, which is
possible to avoid the poor performance that may be caused by human
factors.
Gases to be detected | VOC and so on.Optional configuration: temperature and humidity
measurements. | ||||
Detection range | 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL,
20%, 50%, 100%Vol, can be selected; and other ranges can be
customized. | ||||
Allowable error | ≤±1% F.S (other precision levels can be customized) | ||||
Response time | T90≤20 seconds | Recovery time | ≤30 seconds | ||
Sample gas temperature | -40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature
sampling and cooling filter handle will be possible to detect the
smoke gas at the temperature of 1300 ℃. | ||||
Power supply | 3.6VDC, 6000mA high capacity rechargeable polymer battery | ||||
Display mode | 2.5-inch high-definition color screen | ||||
Detection mode | Built-in pump-suction type measurement, and flow rate at 500 ml /
min. Calibration flow rate should be greater than 500 ml/min, the three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass | ||||
Communication interface | USB (charging and communication), optional: RS232, infrared
communication, automatic recognition | ||||
Data storage | Standard configuration is the data storage capacity for 100, 000
entries; SD card storage function is optional configuration | ||||
Protection level | IP67 | ||||
Explosion-proof mark | Exia II CT6 | ||||
Exterior dimensions | 180×78×33mm (L×W×H) | ||||
Weight | 350g | ||||
Standard accessories | Manual, qualification certificate, warranty card, USB charger
(including the data cable), high-grade aluminum instrument case,
belt clip, humidity dust filter |
The detector is widely used in the petroleum, chemical industry, environmental protection, metallurgy, refining, biochemical medicine, agriculture, and explosion prevention.