PTM600 AQI Portable Gas Monitor Gas Detection Continuous Air Quality Detection

Brand Name:Zetron
Certification:CE
Model Number:PTM600
Minimum Order Quantity:1 set
Delivery Time:1-10 work days
Payment Terms:T/T, Western Union, MoneyGram, D/P, D/A, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: Room 20E, Block 1-A, Oriental Ginza, No. 48 Dongzhimenwai Avenue, Dongcheng,100007, Beijing, China
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

PTM600 AQI Portable Gas Monitor Gas Detection Continuous Air Quality Detection


OVERVIEW


PTM600 portable gas detector has the function of measuring multi gases, temperature and humidity.


The product is provided with high measurement precision, stable performance and simple operation and convenient to carry.
It is possible to simultaneously detect 1 ~6 types of gases, up to 18 or more types of gases, and the types for detection are more than 500 types.



FEATURES & BENEFITS

· Temperature and humidity measurement function
· 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter)
· High temperature sampling and cooling filter handle
· High temperature humidity pretreatment system· External remote sampling pump
· Multiple humidity dust filter· CD-ROM (upper level computer communication software)
· SD card storage
· USB disk storage
· External mini wireless infrared printer
· Built-in mini printer
· Wireless data communications: RS232, infrared communication, automatic recognition


SPECIFICATION

Gases to be detectedArbitrary combination of 1 ~ 6 types of gases which can be expanded to 18 or more types of gases, such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.
Optional configuration: temperature and humidity measurements.
Application scenariosAll the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical,
environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
Resolution0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm),
0.1ppm (0 ~ 1000 ppm),
1ppm (0 ~ 10000 ppm or more),
0.01 mg/l (0 ~ 200 mg/l),
0.1% LEL,
0.01%,
0.001% Vol
Detection principleElectrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor service lifeElectrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years;
catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
Allowable error≤±2% F.S (other or higher precision levels can be customized)
Linearity≤±2%Repeatability≤±2%Uncertainty≤±2%
Response timeT90≤20 secondsRecovery time≤30 seconds
Working environmentTemperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
Sample gas temperature-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.
Temperature and humidity measurementOptional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH
Power supply3.6VDC, 10000mA high capacity rechargeable polymer battery
Display mode3.5-inch high-definition color screen
Detection modeBuilt-in pump-suction type measurement, and flow rate at 800 ml / min. Calibration flow rate should be greater than 800 ml / min,
three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass
Alarm modeIt is possible to set as sound & light alarm, vibration alarm, turning off the alarm.
Communication interfaceUSB (charging and communication), optional: RS232, infrared communication, automatic recognition
Data storageStandard configuration is the data storage capacity for 100, 000 entries; SD card storage and USB disk storage functions are optional configuration.
Protection levelIP66
Explosion-proof typeIntrinsically safe type
Explosion-proof markExia II CT6
Exterior dimensions230×210×120 mm (L×H×W)
Weight2.5Kg
Standard accessoriesManual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case,
built-in humidity dust filter, 0.4 meter stainless steel sampling handle (1 meter of hose, with dust filter, not retractable)
Optional items
Temperature and humidity measurement function, 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1meter), external remote sampling pump, high temperature sampling and cooling filter handle, high temperature humidity pretreatment system, CD-ROM (upper level computer communication software), external mini wireless infrared printer, built-in mini printer, SD card storage, USB disk storage, wireless data communications.


APPLICATION


All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.


China PTM600 AQI Portable Gas Monitor Gas Detection Continuous Air Quality Detection supplier

PTM600 AQI Portable Gas Monitor Gas Detection Continuous Air Quality Detection

Inquiry Cart 0