Deep Cycle 12v lead acid battery voltage 200ah Solar Battery F14 Terminal For Solar UPS System

Brand Name:FOBERRIA
Certification:CE / ISO9001
Model Number:FBR12V
Minimum Order Quantity:50pcs
Delivery Time:25-30days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Site Member
Location: Suzhou Jiangsu China
Address: No.188 Chunxu Road ,Economic Development Zon, Kunshan City, Suzhou, Jiangsu Province, China.
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Deep Cycle 12v lead acid battery voltage 200ah Solar Battery F14 Terminal For Solar UPS System


>Overview


FBR DEEP CYCLE SEALED LEAD ACID BATTERIES provide high performance and brilliant reliability in long period cycling use. Special lead


calcium alloy plate and high purify additive formulation of the deep cycle battery series provides constant power for longer length of time without


shortening the life of the battery.The deep cycle AGM battery series offer an exceptionally long cycle life compared to standard AGM, Mainly


applied for electric systems, security systems, medical equipment, shipping systems, telecommunications equipment, various testing machines,


radio transceiver, the banking uninterruptible power supply system, railway locomotives, railway communications, emergency lighting systems,


small lamps, large UPS and computer backup power, fire extinguishing systems, electronic equipment ,solar power system (off-grid solar power


system, solar street light system, solar garden light system) and wind power system, etc.


>Main Features


Lead acid battery are the most common form for solar battery storage currently on the market.


Battle-tested, thousands of the world's people have used large of lead-acid batteries with solar electricity to remove their need to be


connected to the traditional electricity grid.


The most common setup of lead acid batteries you'll see is usually some kind of rural household installing a bank of batteries + solar panels,


because it's cheaper than paying $30,000 to get the grid extended all the way to their house.


However, some people who have normal access to the grid still elect to go off-grid with a big bank of lead acid batteries.


>Specification
Battery Model No.FBR12V100AhFBR12V90Ah
Nominal Voltage12V12V
Capacity20HR(10.8V)100Ah90Ah
(25ºC)10HR(10.5V)88Ah79Ah
1HR(9.60V)61Ah55.6Ah
DimensionLength330±2mm306±2mm
Width171±2mm169±2mm
Height214±2mm211±2mm
Total height220±2mm214±2mm
Approx. Weight29.5kg±4%27kg±4%
Terminal typeF14F14
Internal resistanceApprox 4.5mΩApprox 5mΩ
(Fully charged,25ºC)
Capacity affected by40ºC102%102%
temperature(20HR)25ºC100%100%
0ºC85%85%
-15ºC65%65%
Self-discharge3monthRemaining Capacity:91%Remaining Capacity:91%
(25ºC)6monthRemaining Capacity:82%Remaining Capacity:82%
12monthRemaining Capacity:65%Remaining Capacity:65%
Nominal operating temperature25ºC±3ºC(77ºF±5ºF)25ºC±3ºC(77ºF±5ºF)
OperatingDischarge-15ºC-50ºC(5ºF-122ºF)-15ºC-50ºC(5ºF-122ºF)
temperature rangeCharge-10ºC-50ºC(14ºF-122ºF)10ºC-50ºC(14ºF-122ºF)
Storage-20ºC-50ºC(-4ºF-122ºF)-20ºC-50ºC(-4ºF-122ºF)
Float charging voltage13.5 to 13.8V13.5 to 13.8V
(25ºC)Temperature compensation:-18mV/ºCTemperature compensation:-18mV/ºC
Cyclic charging voltage14.5 to 15V14.5 to 15V
(25ºC)Temperature compensation:-30mV/ºCTemperature compensation:-30mV/ºC
Max charging current30A27A
Max discharging current800A(5sec.)800A(5sec.)
Designed floating life(20ºC)10years10years
>Structure and composition
ComponentPositive plateNegative plateContainerCoverSeparatorElectrolyteSafety valveTerminal
Raw materialLead dioxideLeadABSABSAGMSulfuric acidRubberCopper
>Discharge diagram
>Application

1. Solar and wind energy storage system;

2. EPS and UPS battery backup;

3. Signal system , emergency lighting system , security system;

4. Telecommunication Equipment;

5. Power source for portable devices or tools.
>FAQ

Q1.What is your warranty time for VRLA battery ?

A1: It depends on battery capacity, depth of discharge, and battery usage. Please kindly contact us for accurate information based on detailed requirements.

Q2. Why battery has different capacity at different hour rate?

A2: The capacity of a battery, in Ahs, is a dynamic number that is dependent on the discharge current.
For example, a battery that is discharged at 10A will give you more capacity than a battery that is discharged at 100A.
With the 20-hr rate, the battery is able to deliver more Ahs than with the 2-hr rate because the 20-hr rate uses a lower discharge current than the 2-hr rate.

Q3. Are you a battery manufacturer, and do you produce the plate by yourself ?

A3: Yes, we are a professional battery manufacture in Fujian Province, China. And we produce plates by ourselves.

Q4. How to proceed with an order?

A4. Firstly let us know your requirements or application. Secondly, We quote according to your requirements or our suggestions.

Thirdly customer confirms the samples and places a deposit for formal order.

Fourthly We arrange the production.

Q5: How about the delivery time?

A5: About 7 days for stock products, around 20 days for half container products, 30 days for 20ft full container products.
China Deep Cycle 12v lead acid battery voltage 200ah Solar Battery F14 Terminal For Solar UPS System supplier

Deep Cycle 12v lead acid battery voltage 200ah Solar Battery F14 Terminal For Solar UPS System

Inquiry Cart 0