0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set

Brand Name:HNMC
Model Number:HES-30
Minimum Order Quantity:1
Delivery Time:30-45 days
Place of Origin:China
Price:Negotiable
Contact Now

Add to Cart

Active Member
Location: Zhengzhou Henan China
Address: No.1207-1, Building #1, the National University Sci-Tech Park of Henan Province, No.11 Changchun Road, Zhengzhou, Henan 450000
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

CT PT TEST Equipment System HES-30


Technical Parameter


HES-30 CT/PT Test Bench


Input Voltage:AC 220V±10%, 50Hz, Single-Phase
Input Current:AC 0-120A
Rated Capacity:30kVA
Output Voltage:AC 0-250V
Output Current:AC 0-120A

HES-1Bx Transformer Tester

Measure item:Ratio errors & Phase errors of the CT and PT
Rated current:5A, 1A
Rated voltage:100V, 110V, 115V, 120V, 150V, 200V, 220V, 230V
Multiplier:1/√3, 1/3, 1, 1.5, 2
Accuracy class:±2%
Operation range:(1%-120%).In, (20%-120%).Un
Frequency:50Hz or 60Hz
Ratio error range:±0.0001% ~ ±19.99% (3 ranges: 0.1999%, 1.999%, 19.99%).
Minimum resolution:0.0001%.
Phase error range:0.01' ~ ±900' (3 ranges: 9.00', 90.0', 900')
Minimum resolution: 0.01'
Impedance range:0.001Ω~ 19.99Ω.
Minimum resolution: 0.001Ω.
Admittance range:0.001 ms ~ 19.99 ms.
Minimum resolution:0.001 ms.
Alarm Function:Provided the sound & light alarm function when the polarity abnormal or ratio inconsistent.

Input Load:

- On Standard CT secondary side: ≈0.11Ω, COSφ≈1.0

- On Test Object CT secondary side: ≈0.003Ω, COSφ≈1.0

- On Standard PT secondary side: ≈0.05VA (100V)

Communication Interface:Provided the RS232 serial PC communication interface
Display model:LCD
Power supply:AC 220V±10%, 60Hz
Power consumption:< 20VA
Product Type:Portable type.

CT Burden FY47-49

Rated Current:5A, 1A

Power Factor

and Rated Burden:

In=5A:

COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA

(more option available)

In=1A:

COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA

(more option available)

Accuracy Class:±3%
Operation Range:(1%-120%). In
Frequency:50Hz or 60Hz
Withstand Voltage:2kV/1min
Insulation:Air
Operating Model:Short-time (Used in CT Accuracy Testing System)
Product Type:Portable type.

High-current Test Cables of the CT

Cables includes: 3000A(600mm2) x 3m x 2pcs, 1000A(200mm2) x 5m x 1pc

500A(100mm2) x 3m x 2pcs, 250A(50mm2) x 3m x 2pcs


HLB-50G1 Standard CT



Rated Primary Current(A):

5, 7.5, 10, 12.5, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 125, 150, 160, 200, 250, 300, 315, 350, 400, 450, 500, 600, 630, 700, 750, 800, 900, 1000, 1200, 1250, 1400, 1500, 1600, 1800, 2000, 2500, 3000, 3150, 3500, 4000, 4500, 5000A

(more option available)

Rated Secondary Current:5A, 1A
Rated Current Ratio:5A~5000A/5A, 5A~5000A/1A (more option available)
Accuracy Class:0.01S% (0.05%, 0.02%, 0.01% or better are available)
Rated Secondary Burden:0.2Ω (Burden is 5VA at I2 = 5A, Burden is 0.2VA at I2 = 1A)
Power Factor:COSΦ=1.0
Operating Range:(1%-120%). In

Connection Mode:

Fixed connection terminals at Pri.current range is 5A-450A

Pass-through connection with 2 turns at Pri.current range is 500A-900A

Pass-through connection with 1 turn at Pri.current range is 1000A-5000A

Frequency:50Hz or 60Hz
Voltage Level:AC 600V
Withstand Voltage:2000V 1min
Insulating Medium:Air

SLQ-30KVA Current Generator


Input Voltage:AC 0-250V
Output Current:AC 0-5000A
Rated Capacity:30kVA
Rated Input Current:AC 120A
Frequency:50Hz or 60Hz
Current Output Model:

Fixed terminal at current is 50A, 200A, 500A

Through-hole connection at current is 500A-5000A

Products Shape:Stainless Steel Box
Working condition:0 - 40ºC, RH ≤ 90%

FY95-1 PT Burden

Rated Voltage:100V, 100/√3V, 100/3V
Power Factor:COSФ=0.8, COSФ=1.0
Rated Burden (VA):

1.25VA, 2.5VA, 5VA, 10VA, 20VA, 40VA, 50VA, 80VA, 100VA

(more option available)

Total Output Burden:308.75VA (more option available)
Accuracy Class:±3%
Operation Range:(20%-120%). Un
Frequency:50Hz or 60Hz
Withstand Voltage:2kV/1min
Insulation:Air
Operating Model:Short-time (Used in PT Accuracy Testing System)

HJB-220G3 Standard PT

Rated Primary Voltage:110/√3kV, 220/√3kV
Rated Secondary Voltage:110V, 110/√3V, 100V, 100/√3V

Rated Voltage Ratio:

110/√3/0.11/√3kV, 110/√3/0.11kV, 110/√3/0.1/√3kV, 110/√3/0.1kV

220/√3/0.11/√3kV, 220/√3/0.11kV, 220/√3/0.1/√3kV, 220/√3/0.1kV

Accuracy Class:0.05% (100/√3V,110/√3V), 0.1% (100V,110V)
Rated Secondary Burden:0.2VA(110V, 100V), 0.07VA(110/√3V, 100/√3V)
Power Factor:COSΦ=1.0
Operating Range:(20%-120%). Un
Frequency:50Hz /60Hz
Insulation:SF6 Gas


HJC-80 Resonant High Voltage Source



Product Application:

The system is a voltage generator, and used for Capacitive PT accuracy testing with 110/√3kV and 220/√3kV voltage level
Rated input voltage:AC 220V
Rated output voltage:AC 0~200 kV
Rated Capacity:200 kVar
Max output current:AC 1.0 A
Frequency:50Hz or 60Hz
The capacitance of the object CVT:0.004uF ~0.02uF
Operating Condition:Temperature: -10oC ~ +50 oC
RH: up to 85% (max. 90%, non-condensing)

LCB-10KVA/10KV Exciting Transformer

Input Voltage:AC 0 - 250V, 50Hz
Output Voltage:AC 0 - 10kV, 50Hz
Output Current:AC 0-1A
Rated Capacity:10kVA
Insulation:Dry type
Weight:~ 50 kg

DKQ-40KVA/40KV Reactor

Rated Capacity:40kVA/stage
Rated Voltage:AC 40 kV/stage
Rated Current:AC 1 A/stage
Inductance Range:125H-500H/stage
Insulation:Epoxy resin casting
Weight:~ 60 kg/stage
Quantity:5pcs

China 0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set supplier

0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set

Inquiry Cart 0