High Stability Power Meter Test Equipment Thermal Overload Protection

Brand Name:HNMC
Model Number:UTI-3S
Minimum Order Quantity:1
Delivery Time:30-45 days
Payment Terms:L/C, T/T, Western Union
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Zhengzhou Henan China
Address: No.1207-1, Building #1, the National University Sci-Tech Park of Henan Province, No.11 Changchun Road, Zhengzhou, Henan 450000
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

High Stability Class 0.05 Portable Three Phase Standard Power Source UTI-3S


1) Can be used independently or together with standard meter

2) With measurement mode selection namely 3P3W, 3P4W and 1P2W

3) Power Source (PS): output 0-380V/phase & 1mA-20A/phase, depend on client requirement

4) Linear amplifier

5) Automatic control by PC software

6) Manual control by touch screen/keypad


Technical Index

Description1mA-20A, accuracy class 0.05 or 0.1
Supply VoltageAC 85-282V, 47-63HZ
Power Consumption290VA
Influence of auxiliary voltage≤0.005% at 10% variation
Dimension510*600*170mm
Weight20KG
Frequency Range45-69HZ
Frequency Resolution0.001HZ
Frequency ErrorLess than 0.01HZ
Phase Angle Range0-359.99°
Phase Angle Resolution0.001°
Phase Angle Error0.1°
Communication PortRS232
Range (P-N)0-456V
Power3*15VA
Display ResolutionSix significant digits
Output accuracy0.1%
Output stabilityBetter than 0.01%/1min
DistortionBetter than 0.5%
Range1mA-20A
Power3*15VA
Display ResolutionSix significant digits
Output accuracy0.1%
Output stabilityBetter than 0.01%/1min
DistortionBetter than 0.5%
Fundamental Frequency range40-70HZ
Range2-31st times
Maximum content in both voltage and current circuit40%
Active power0.1%
Reactive power0.2%
Apparent power0.1%
Power factor0.1%
Voltage0.1%
Current0.1%
Phase0.1°

Features


1) Can be controlled by computer through RS232 setting the parameters and then test by control software;

2) Can be used independently also can be used together with reference standard meter.

3) With LED indicator on the face plate after power on the unit

4) With voltage measurement facility and loop back control

5) With measurement mode selection, namely 3P3W, 3P4W and 1P2W. When select 3P3W, automatically

deactivate L2 phase current and when select 1P2W, automatically deselect L2 and L3 phases.

6) With overload, short circuit and thermal overload protection

7) When accuracy of the unit changes, can calibrate it by given method by yourself


Display below parameters (7” LCD)


1) True RMS value of voltage for each phase

2) True RMS value of phase to phase voltage

3) Harmonics distortion in each phase and total harmonic distortion

4) Phase current

5) Phase angle between voltages

6) Phase angle between voltage and current

7) Active, reactive and apparent power of each phase

8) Total power factor

9) Total active, reactive and apparent power

10) Instantaneous power factor for each phase

11) Frequency

12) Vector diagram