UPS Multifunction Environment Meters 12v Battery Tester For
Electric Vehicles
VICTOR 3015A/3015B/3015C Battery Tester For Electric Vehicles UPS
Batteries Solar Energy Battery System Analyzer
Products Introduction
The instrument can quickly, simply, accurately and reliably judge
the no-load energy, the on-load condition, the internal resistance
of
the battery and the charging system conditions of 6V and 12V lead-
acid accumulator. The instrument, provided with 32-bit high-end
micro
control unit for computation operation, can automatically judge the
batteries with different voltages (6V or 12V) at the same time and
the
charging state thereof. Moreover, the instrument is internally
provided with reverse polarity protection, over voltage input
protection, poor
contact prompt and over-temperature prompt. Therefore, the test can
be smoothly, simply and conveniently carried out.
The on-load test method recommended by the international battery
association is adopted for the instrument. Specifically, the
corresponding mode is selected and set in advance according to the
rated capacity of the accumulator tested thereby, and the
short-time
heavy load discharge of the battery is controlled to detect the
discharge conditions of the batteries at the same time, and three
LED
indicator lights are adopted to simply and conveniently display the
test result. The test process of the instrument and the data result
judgment
are processed by the internal arithmetic unit. Additionally, the
test result can be reviewed.
The instrument shell is made of solid ABS engineering materials,
and the load heating simulation part is up and down installed with
stainless steel porous plate, and the fan is configured to
strengthen heat dissipation in order to make the test process more
stable and
more reliable. The test line part is composed of thick pure copper
test wire, and is also configured with four-wire Kelvin test clamp
for
connection. The test sampling data are directly sampled from the
outgoing terminal of the battery in order to really recover the
battery
working condition in the battery working process and make the test
result more accurate.
Excellent materials, reliable process and design, advanced circuit
control, good workmanship and quality control system can ensure the
high quality, accuracy and reliability of the instrument.
Specification and Parameters
1. The instrument is applicable to common 6V and 12V lead-acid
accumulators.
2. Load test current: about 20A.
3. Accumulator capacity detection range: 5Ah ~ 80Ah.
4. Maximum voltage: DC 19.99V.
5. Internal resistance range of battery: 1.00milliohm ~ 99.99
milliohm.
6. LED status indication: Battery condition: “Green” (Sufficient
Capacity), “Yellow” (Insufficient Capacity), “Red” (Replace
Battery);
Charging system: “Green” (Normal Charging), “Yellow” (Abnormal
Charging).
7. Accumulator capacity presetting: continuously adjustable in the
range of 5-80Ah, with 5Ah increment.
8. Test time: less than 10s; test time interval: it is suggested as
about 5min.
9. Poor contact prompt for test clamp; reverse clamp connection
protection; input over voltage protection.
10. Using condition: -10℃ 55 relative humidity: lower than 80%.
11. Product dimension: about 9.5*5.0*19cm; dead weight: about 860g.
◆ Indication Diagram for Instrument
Technical Data
3015A | 3015B | 3015C |
6/12V batteries, ≤20A discharge, 5~80AH test range | 6/12V batt eries, ≤80A discharge, 40~200AH test range | 6/12V batteries, ≤80A discharge, 40~200AH test range |
The internal resistance of battery will be tested synchronously | The internal resistance of battery will be tested synchronously | The internal resistance of battery will be tested synchronously |
Micro-computer strictly control the discharge time, to reduce the
battery damage | Micro-computer strictly control the discharge time, to reduce the
battery damage | Micro-computer strictly control the discharge time, to reduce the
battery damage |
Over-temperature, anti-burning and reverse polarity protection | Over-temperature, anti-burning and reverse polarity protection | Over-temperature, anti-burning and reverse polarity protection |
The meter will make a judgement automatically since the test
finished; sound and light indicate | The meter will make a judgement automatically since the test
finished; sound and light indicate | The meter will make a judgement automatically since the test
finished; sound and light indicate |
Tested reading hold automatically | Tested reading hold automatically | Tested reading hold automatically |
Clear and direct-viewing display with four digits | Clear and direct-viewing display with four digits | |
Discharge time: less than 10s | Discharge time: less than 10s | Discharge time: less than 10s (for dynamic batteries measuring) |
Battery amp hour rating testing range : 5-80AH | Battery amp hour rating testing range : 40~200AH | Battery amp hour rating testing range : 40~200AH |
Internal resistance range of battery: 0~99mΩ | Internal resistance range of battery: 0~99mΩ | Internal resistance range of battery: 0~99mΩ |
Usable scope: applicable to the dynamical type battery such as the
batteries supply for electric bicycle, UPS batteries, solar storage
energy batteries | Usable scope: applicable to the dynamical type battery such as the
batteries supply for electric bicycle, UPS batteries, solar storage
energy batteries | Usable scope: starter battery (car battery) Dynamic accumulator: applicable to the dynamical type battery such
as the batteries supply for electric bicycle, UPS batteries, solar
storage energy batteries |
| | Starter battery range: CCA: 100~1700 IEC: 100~1000 EN:100~1700 DIN: 100~1000 |
| | This is a battery tester which contains both testing method of
dynamical battery and starter battery |