Add to Cart
RS232 RS485 COM Port Integrated HMI PLC 64MB Public Terminal Isolated
RS232 RS485 COM Port Integrated HMI PLC Passive NPN Public Terminal Isolated Digital Input
The all-in-one solution is to integrate the controller, operation interface, input/output, analog input/output, high-speed counting/pulse and communication port into a compact unit to meet the needs of customer equipment automation control.
Parameter:
Display | Dimension | 275*194*36mm |
Cutout size | 262*180mm | |
Type | 10"TFT | |
Feature | 60K-color resistive touch screen, supports portrait display | |
Memory | RAM | 64MB |
ROM | NOR Flash 16MB | |
CPU | 32bit CPU 408MHz | |
I/O | DI/DO | Max 30DI/30DO (max 28MR) |
DI/DO level | Input: Passive NPN, public terminal isolated Transistor output: Low level NPN, COM connect to negative; Relay output: Normally open dry contact | |
DO type and load | Relay MR/MOS tube, MOS tube: 2A/point, 4A/4 point COM, 5A/12 point COM; MR: 2A/point, 5A/12 point COM. | |
Analog I/O (optional) | Max 16AI/8AO | |
AI type (optional) | Thermocouple E/E_/K/K_/S/S_/T/T_/J/J_ / PT100/ PT1000/ NTC10K/ NTC50K/ NTC100K/ 0~10V/ 0~5V/ 0~20mA/ 4~20mA/ -5V~5V/ -10V~10V / mixed | |
AO type (optional) | 0~10V /0~5V/ 0~20mA/ 4~20mA/ mixed/ -5~5V/ -10~10V (2AO for 1 minus voltage) | |
High-speed function | High-speed counting | Single phase 6 channel 60KHz, or 2 AB 60KHz + 1 AB 10KHz, or 2 ABZ 60KHz + 1 AB phase 10 KHz |
High-speed pulse | 8 channels, Y0-Y3 is 100KHz, Y4-Y7 is 10KHz. High-speed counting + high-speed pulse < 480KHz | |
Connection | HMI | Type-B HMI download port (can download PLC program through the USB penetrating function), RS232 |
1 RS485 (changed from default RS232) | ||
PLC | 1 Mini USB, 1 RS232 (program port) | |
1 RS485 or 2 RS485 COM ports (one is changed from the default RS232 port) | ||
CAN (2.0A/B) port, Ethernet port, WIFI (will occupy default RS232 port) | ||
Software | HMI | Coolmay mView HMI Programming Software |
PLC | Compatible with GX Developer 8.86 and GX WORKS 2 |
Advantage:
◆ Upper computer programming software compatible with Works 2/GX Developer8.86 (supports Ladder diagram and SFC language, does not support structured programming/labels).
◆ Powerful, compatible with FX3G/FX3U/FX3S PLC, high processing speed.
◆ Military level 32 bit CPU adopted, which is faster and more adapted to industrial environment of high electromagnetic interference.
◆ Special encryption, prevent illegal reading thoroughly. 8-bit encryption, 12345678 as password can thoroughly prevent reading of ladder logic program.
◆ Clock supported, rechargeable battery adopted.
◆ Default with 1 HMI download port, 2 PLC programming ports (RS232/MiniB USB port or Type-C), and one USB port.
◆ Convenient wiring. All wiring terminals adopt 3.81 pitch pluggable terminals, which is convenient for customers to use.
◆ Flexible use. More specifications and batches can be customized according to customer requirements.
◆ 32K program capacity, 32K retentive register, support interrupt, linear arc interpolation ,PID auto-tuning, high powerful.
◆ The PLC is compatible with Mitsubishi programming software, and the HMI uses TK series human-machine interface programming software mView.
PLC analog wiring:
Two-wire system: the positive pole of the power supply is connected to the positive pole of the transmitter; the negative pole of the transmitter is connected to the AD side; the negative pole of power supply is connected to GND, which normally it is wring way of 4-20mA/0-20mA transmitter.
Three-wire system: the positive pole of the power supply is connected to the positive
pole of the transmitter; the negative pole of the power supply and
the negative pole of the signal output are the same terminal and
transmitter signal output is connected to the AD terminal.
Four-wire system: the positive and negative poles of the power supply are
respectively connected to the positive and negative poles of the
power supply of the transmitter,and the positive and negative poles
of the transmitter signal output are respectively connected to the
AD and GND terminals.
The analog line of the temperature is connected to the AD terminal
and the GND terminal respectively. if I is a three-wire Pt100, it
needs to be connected in two lines. The GND common terminal of the
analog input and output can be shared.
Application scenario:
Food packaging machinery, electronic manufacturing equipment, printing machinery, textle machinery, medical machinery testing machinery, wind powerequipment,engineering machinery, plastic machinery tobacco machinery, agriculture, forestry and animal husbandry (aquaculture), environmental protec-tion equipment, automobile manufacturing,AGV trolleys,logistics storage equipment...