Settled Fe Probe Coating Thickness Gauge Film Thickness Tester

Brand Name:LEEB
Certification:CE, FCC EAC & ISO
Model Number:Leeb250A
Minimum Order Quantity:1 Set
Delivery Time:In 7-10 work days
Payment Terms:T/T, PayPal, Western Union, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Chongqing Chongqing China
Address: High&New Technology Industrial Park, Yubei District, Chongqing, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Settled Fe Probe Coating Thickness Gauge Film Thickness Tester


Settled Fe Probe And Plastic Shell Coating Thickness Gauge With Switch off automatically or manually



Functions & Features

● High quality metal probes.
● Two measuring methods:continuous and single;
● Two working mode: direct and batch;
● Limit setting function.
● Switch off automatically or manually.

Measuring Materials
Magnetic Induction (Fe): Measuring the thickness of Non-magnetic coating on magnetic metal substrate,
such as aluminum, chromium, copper, zinc, rubber, paint on the base of steel, iron, alloy and magnetic
steel


Technical Parameters


Technical Parameters
Model No.Leeb250A
Measuring principleFe
Measuring range (µm)0~1250μm
ProbeSettled
ShellPlastic
Accuracy±(1~3%H+1) μm; H refers to the thickness of testing piece
Minimum resolution (µm)0.1μm
Min curvature of the min area (mm)Convex1.5 Concave9
Diameter of the min area (mm)Φ7
Critical thickness of substrate (mm)0.5
Memory200 groups measured data
Dimensions115*55*23mm
Power supplyAAA Alkaline battery
Standard Configuration
Main unit,5 calibration specimens (48.5μm,99.8μm,249μm,513μm 1024μm),1 probe & substrate
Optional Accessories
Probes,Specimens,1 leather sheath

Troubleshooting
The following error information table to tell you how to identify and troubleshoot:
Error code
Implications of error code
The cause and solution
E02
Probe or instrument damageRepair probe or instrument
E03
Probe or instrument damage
Repair probe or instrument
E04
Measured values occur large fluctuations
(For example when soft layer measurements);
Magnetic field effect
When the measure menton
the softcover, auxiliary device to
measure should be adopted;Stay away from the
strong magnetic field environment
E05
Too close to the probe from the metal substrate when the phone is switched on
Probe from the metal substrate
E08
Probe or instrument damage
Repair probe or instrument
E11
Probe model in conformity with this group of the original data corresponding to the probe model
Replace the suitable probe
Choose an unused group units
Delete after calibration again
E15
Zero deviation is too big, can not be zero
Select the appropriate substrate or repair equipment
E20
This set of unit for calibration value
Choose an unused group unit Or delete after calibration again