MATERIAL NUMBER:
8BVI0055HWD0.000-1
DESCRIPTION:
  • Integrated uncontrolled standstill and safe stop
  • Integrated connection for motor holding brake and temperature sensor
  • 2 slots for ACOPOSmulti plug-in modules
  • Two fully independent power inverters in one inverter module contained in 2-axis modules
ACOPOSmulti inverter module, 7.6 A, AS, wall mounting, 2 axes
General information
B&R ID code0x20B5
Cooling and mounting typeWall mounting
Slots for plug-in modules2
Certifications
CEYes
Functional safetyYes
ULcULus E225616
Power conversion equipment
EACYes
KCYes
DC bus connection
Voltage
Nominal750 VDC
Continuous power consumption11.19 kW
Power dissipation depending on switching frequency
Switching frequency 5 kHz[1.2 * IM² + 2.62 * IM + 100] W
Switching frequency 10 kHz[2.56 * IM² + 2.8 * IM + 200] W
Switching frequency 20 kHz[6 * IM² - 9.4 * IM + 430] W
DC bus capacitance330 µF
VariantACOPOSmulti backplane
24 VDC power supply
Input voltage25 VDC ±1.6%
Input capacitance23.5 µF
Max. power consumption16 W + PSLOT1 + PSLOT2 + P24 V Out + PHoldingBrake(s)
VariantACOPOSmulti backplane
24 VDC output
Quantity2
Output voltage
DC bus voltage (UDC): 260 to 315 VDC25 VDC * (UDC/315)
DC bus voltage (UDC): 315 to 800 VDC24 VDC ±6%
Fuse protection250 mA (slow-blow) electronic, automatic reset
Motor connection
Quantity2
Continuous power per motor connection5.5 kW
Continuous current per motor connection7.6 Aeff
Reduction of continuous current depending on switching frequency
Switching frequency 5 kHzNo reduction
Switching frequency 10 kHz0.22 A/K (starting at 43°C)
Switching frequency 20 kHz0.15 A/K (starting at -14°C)
Reduction of continuous current depending on installation elevation
Starting at 500 m above sea level0.76 Aeff per 1000 m
Peak current per motor connection18.9 Aeff
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Protective measures
Overload protectionYes
Short-circuit and ground fault protectionYes
Max. output frequency598 Hz
Variant
U, V, W, PEConnector
Shield connectionYes
Terminal connection cross section
Flexible and fine-stranded wires
With wire end sleeves0.25 to 6 mm²
Approbation data
UL/C-UL-US30 to 10 AWG
CSA28 to 10 AWG
Terminal cable cross section dimension of shield connection12 to 22 mm
Max. motor line length depending on switching frequency
Switching frequency 5 kHz25 m
Switching frequency 10 kHz25 m
Switching frequency 20 kHz10 m
Motor holding brake connection
Quantity2
Output voltage24 VDC +5.8% / -0%
Continuous current1.1 A
Max. internal resistance0.5 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation1.5 Ws
Max. switching frequency0.5 Hz
Protective measures
Overload and short-circuit protectionYes
Open-circuit monitoringYes
Undervoltage monitoringYes
Response threshold for open-circuit monitoringApprox. 0.25 A
Response threshold for undervoltage monitoring24 VDC +0% / -4%
Enable inputs
Quantity4 (2 per axis)
CircuitSink
Electrical isolation
Input - Inverter moduleYes
Input - InputYes
Input voltage
Nominal24 VDC
Maximum30 VDC
Input current at nominal voltageApprox. 30 mA
Switching threshold
Low<5 V
High>15 V
Switching delay at nominal input voltage
Enable 1 → 0, PWM offMax. 20.5 ms
Enable 0 → 1, ready for PWMMax. 100 µs
Modulation compared to ground potentialMax. ±38 V
OSSD signal connectionsPermitted
Max. test pulse length: 500 µs
Trigger inputs
Quantity2
CircuitSink
Electrical isolation
Input - Inverter moduleYes
Input - InputYes
Input voltage
Nominal24 VDC
Maximum30 VDC
Switching threshold
Low<5 V
High>15 V
Input current at nominal voltageApprox. 10 mA
Switching delay
Rising edge52 µs ±0.5 µs (digitally filtered)
Falling edge53 µs ±0.5 µs (digitally filtered)
Modulation compared to ground potentialMax. ±38 V
Electrical properties
Discharge capacitance0.2 µF
Operating conditions
Permissible mounting orientations
Hanging verticallyYes
Horizontal, face upYes
Standing horizontallyNo
Installation elevation above sea level
Nominal0 to 500 m
Maximum4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20
Ambient conditions
Temperature
Operation
Nominal5 to 40°C
Maximum55°C
Storage-25 to 55°C
Transport-25 to 70°C
Relative humidity
Operation5 to 85%
Storage5 to 95%
TransportMax. 95% at 40°C
Mechanical properties
Dimensions
Width53 mm
Height317 mm
Depth
Wall mounting263 mm
WeightApprox. 2.9 kg
Module width1