ALR121-S50 YOKOGAWA Serial Communication Modules 4-wire System Multipoint SCS Modbus Communication

Brand Name:Yokogawa
Certification:CO
Model Number:ALR121-S50
Minimum Order Quantity:1 Piece
Delivery Time:3-5 working days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Xiamen Fujian China
Address: Unit 1602, Top Plaza, No.2 Lujiang Road, Siming District, Xiamen Fujian China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

ALR121-S50 YOKOGAWA Serial Communication Modules 4-wire System Multipoint SCS Modbus Communication


Description:


By using the SCS’s Modbus slave communication function, the data in SCS can be set or referred to by the Modbus master which is as separate system from SCS via a serial communication module. Furthermore, the subsystem data such as from sequencers can be set or referred to via a serial communication module using SCS’s subsystem communication function.


The dual-redundant configuration of the network can be available by establishing an independent transmission path from the Modbus master for every two the serial communication modules mounted in the SCS.


However, control/ stand-by switching function in between the dual-redundant serial communication modules mounted on adjacent slots is not supported.



Communication module’s definition information, Modbus device addresses, mapping definition of SCS data, and so on are to be downloaded using engineering function of a Safety Engineering Station (SENG).


When a data is sent from an external Modbus master (external device), the SCS’s CPU receives it through its serial communication module. The SCS’s CPU sends a response message using the Modbus slave communication function to the Modbus master in response to the data request.


The SCS Maintenance Support Tool displays error information and notifies the error status using the SCS status display function when an error in the serial communication module and communication content occurs.


Product Details:


Brand NameYOKOGAWA
ModelALR121-S50
ConditionNew
Gross Weight/Shipping Weight2.2 lbs / 35.2 oz / 1kg
Packing Size6.4" x 6.4" x 4.8" (16cm x 16 cm x 12 cm)
Country of Origin/Original CountryUnited States (USA)
Lead TimeIn Stock
Shipping PortXiamen
PaymentT/T
Sales PriceInquiry
ColorDepend on product
Warranty12 months
Lead time5-8 work days
Courier partnersDHL, UPS, TNT, FedEx and EMS


Additional Information:


Features
Suffix Codes-SStandard type
5With no explosion protection
EWith explosion protection
1With ISA Standard G3
BWith ISA Standard G3 and temperature
InterfaceRS-422/RS-485 (4-wire system)
Connection methodPoint-to-point (RS-422) Multipoint (RS-485)
Communication functionHalf-duplex
Synchronization methodStart-stop synchronization
Transmission speed1200/2400/4800/9600/19200/38400 bps
Transmission codeBinary
Character length8 bits (Fixed to 8 bit on the Modbus slave communication function and the subsystem communication function)
Stop bit length1/2 bits (Fixed to 1 bit on the subsystem communication function)
Parity checkNone/even/odd
Lag time after data transmission1 ms
Transmission distanceMaximum 1200 m (total extended length)
I/O wiringCable with 3-pair shield, AKB161, or AKB162
Wiring connectionClamped with terminal block’s M4 screws (5 poles × 2 ports)
Communication functionModbus slave communication function, subsystem communication function
Current consumption0.5 A



Datasheet Link:Yokogawa ALR121-S50.pdf

China ALR121-S50 YOKOGAWA Serial Communication Modules 4-wire System Multipoint SCS Modbus Communication supplier

ALR121-S50 YOKOGAWA Serial Communication Modules 4-wire System Multipoint SCS Modbus Communication

Inquiry Cart 0