GKL221 Total Station Battery Charger GEB241 Survey Instrument Accessory

Brand Name:Leica
Certification:ISO
Model Number:GKL221
Minimum Order Quantity:5 Pieces
Delivery Time:3-5 work day
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Zhengzhou China
Address: No.29 Fengyang Road, Zhengzhou City, China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Survey Instrument Accessory Leica GKL221 Battery Charger for Leica Total Station Battery GEB241 GEB242


Model: GKL221


Specifications:

ModelGKL221
ColorBlack
BatteriesLeica GEB241 GEB242
Input20V/24V-1A MAX
Output18.5A-1A MAX
Charger Adapter:US/EU/UK/AU/PLUG adapter
Used ForTotal Station
Weight520g
TypeElectric
CertificateCE RoHS
Warranty1 year
PackageOPP+bubble bagouter packing

Features:

1. Used For Leica Total Station Battery GEB241 GEB242

2. Brand new and with high quality

3. Abundant Stock

4. With high quality power, long life, reliable and long working hours

5. With PTC protection device, prevents overcharging, discharging, short circuit, and overheating.


Charging the batteries

New and stored batteries

New NiCd and NiMH batteries reach their maximum capacity only after a few charging and discharging cycles. The batteries should be fully discharged and charged three to five times. NiMH batteries that have been stored and not used for an extended period (more than a month) should be refreshed simularly. For Li-Ion batteries, a single discharging and charging cycle is sufficient. The easiest way to perform this cycling is by using the GKL221 Charging Station which has a discharge function. Alternatively, the batteries can be charged and then placed in the related survey equipment during normal use and discharged until the equipment switches off.


Batteries in regular use

After use the battery can be placed in the charger until fully charged (the green light flashes). The charging time depends on the battery capacity and temperature.


Charging temperature

The charging temperature (ambient temperature) has a significant impact on the life of the batteries. Charging at high temperature can cause loss of capacity. These losses in capacity are irreversible. Even with several charging and discharging cycles, the original capacity can no longer be obtained. For optimal charging, we recommend that the batteries be charged at ambient temperatures as low as possible (+10 °C to +20 °C / +50 °F to +68 °F). The permitted temperature range in which charging can still be performed is between 0 °C and +35 °C (+32 °F and +95 °F). Due to a temperature control mode built into the GKL221, GKL211 and GKL112, charging at temperatures that may cause damage to the batteries is not possible.


China GKL221 Total Station Battery Charger GEB241 Survey Instrument Accessory supplier

GKL221 Total Station Battery Charger GEB241 Survey Instrument Accessory