The submersible liquid level sensor is a pressure sensor that measures the liquid level. Based on the principle that the static pressure of the measured liquid is proportional to the height of the liquid, it uses an isolated diffused silicon sensitive element or a ceramic capacitive pressure sensitive sensor to convert the static pressure into The electrical signal is converted into a standard electrical signal after temperature compensation and linear correction, which is generally suitable for liquid level measurement of various media in petrochemical, metallurgy, electric power, pharmaceutical, water supply and drainage, environmental protection and other systems and industries.
Parameter Submersible Sewerage Slurry Sludge Level Sensor
Measure range
Gauge pressure | ||||||||
H2O | Range | 0…1 | 0…3 | 0…5 | 0…10 | 0…20 | 0…50 | 0…100 |
overload | 3 | 10 | 10 | 25 | 50 | 100 | 200 |
Absolute pressure | ||||||||
H2O | Range | 0…20 | 0…50 | 0…100 | ||||
overload | 50 | 100 | 200 |
Output signal
Current (2-wire system) | 4…20mA |
Voltage (3-wire system) | DC 0…10V ;DC 0…5V;DC 1…5V |
DC 0.5…4.5V | |
Proportional voltage (3-wire system) | DC 0.5…4.5V |
Digital output | 4…20mA+Hart |
4…20mA+RS485 | |
RS485 ;I2C |
Load (Ω)
Current (2-wire system): ≤ (power supply voltage-8V) /0.02A
Voltage (3-wire system):> Maximum output signal / 1mA
Proportional voltage (3-wire system):> 10K
Supply voltage
Output signal | Power | |
standard | Optional | |
4…20mA | DC 8…30V | |
DC 0…10V | DC 14…30V | |
DC 0…5V | DC 8…30V | DC 3…5V |
DC 1…5V | DC 8…30V | DC 3…5V |
DC 0.5…4.5V | DC 8…30V | DC 3…5V |
DC 0.5…4.5V(Proportional voltage) | DC 5V±10% | |
4…20mA+Hart | DC 12…30V | |
4…20mA+RS485 | DC 8…30V | |
RS485 | DC 8…30V | DC 3…5V |
I2C | DC 3…5V |
Total current consumption
Current (2-wire system): signal current, maximum 25mA
Voltage (3-wire system): 2.5mA
Proportional voltage (3-wire system): 2.5mA
Accuracy
Room temperature accuracy | standard | Optional |
Complies with JJG 860, JJ G882 standards | ||
Range ≧ 10H2O | 0.1%FS | 0.25%FS;0.1%FS |
Range ≧ 3H2O | 0.1%FS | 0.25%FS |
Range ≧ 1H2O | 0.1%FS | 0.5% FS |
Temperature range
standard | Optional | ||
Operating temperature | -20℃~85℃ | -40℃~125℃ | |
Compensation temperature | 10H2O≧Range | 0℃~50℃ | |
10H2O≤Range | 0℃~70℃ | -10℃~80℃ | |
storage temperature | -40℃~125℃ |
Temperature drift
standard | Optional | ||
Zero temperature drift | 1H2O≧Range | ±0.05%FS/℃ | ±0.02%FS/℃ |
10H2O≤Range | ±0.03%FS/℃ | ±0.02%FS/℃ | |
Full-scale drift | 1H2O≧Range | ±0.05%FS/℃ | ±0.02%FS/℃ |
10H2O≤Range | ±0.03%FS/℃ | ±0.02%FS/℃ |
Long-term stability
≤0.2%FS/year@0.5%FS
Response time
Range | standard | Optional | |
boot time | 100ms | 10ms | |
Response time | 10ms | 1ms | |
stable schedule | ≧10H2O | 15s | |
≤10H2O | 1min |
Anti-vibration
10g (IEC 60068-2-6 standard, under resonance conditions)
Impact resistance
500g (IEC 60068-2-27 standard, mechanical shock)
Service life
1 million pressure cycles
Features
1, high-quality sensor with high sensitivity, fast response speed, accurately reflect the flow or static level of subtle changes, high measurement accuracy.
2, with safety and isolation ability, can be used in a variety of dangerous places.
3, with anti-clogging design, can achieve the measurement of paste medium level.
4, simple installation, easy to use, strong communication ability.
5, such as scale, LED, LCD three indicator head, field reading is very convenient.
6, 4-20mA DC two-line signal transmission, strong anti-interference ability, long transmission distance.
7, fine special zero, temperature drift, nonlinear compensation, to ensure the accuracy of the instrument in the range of conditions of use, long-term stability.
8, solid structure, no moving parts, high reliability, long service life, from water, oil to viscosity of the paste can be accurately measured, not affected by foaming, deposition, the electrical characteristics of the measured medium has a wide temperature compensation range. Hydrostatic input level meter has power reverse polarity protection and overload current limiting protection.
9, input type, straight rod type, screw type, plug type, with blocking type design, simple installation, easy to use, strong exchange ability, high quality sensor sensitivity, fast response, accurately reflect the flow or static liquid level changes, high measurement accuracy.
Applications Submersible Sewerage Slurry Sludge Level Sensor
Ordering Information Submersible Sewerage Slurry Sludge Level Sensor
YD322 | submersible transmitter | |||||
Range | 0~1...200m | |||||
(0-X)m | X: Range | |||||
Code | Power supply | |||||
D1 | 24VDC | |||||
D2 | Others | |||||
Code | Output signal | |||||
S1 | 4~20mADC | |||||
S2 | 1~5VDC | |||||
S3 | 0~5VDC | |||||
S4 | 0~10mAC | |||||
S5 | 0~20mAC | |||||
S6 | 0~10VDC | |||||
Code | Cable length/Infix depth/length of flexible pipe | |||||
L | Actual length |