Add to Cart
Smart 4-20mA online display oil turbine flow meter liquid turbine flow meter
Description
The liquid turbine flowmeter is suitable for the measurement of
liquids. The medium is required to be clean, and a filter must be
installed. The instrument has high accuracy, good repeatability,
compact structure, easy installation and maintenance, and high
pressure resistance.
Applicable medium: liquid
Inapplicable medium: gas, steam
The medium is required to be clean, and a filter must be
installed
Detailed Image
Specification
Nominal diameter: Pipe type: DN4~DN200 Insertion type: DN100~DN2000 Accuracy class: Pipeline: ±0.5 class, ±1.0 class Plug-in: ±1.5 class, ±2.5 class, high precision up to 0.2 class Ambient temperature: -20℃~50℃ Medium temperature: Measuring liquid: -20℃~120℃ Measuring gas:
-20℃~80℃ Atmospheric pressure: 86KPa~106KPa Nominal pressure: 1.6Mpa, 2.5Mpa, 6.4Mpa, 25Mpa Explosion-proof grade: ExdIIBT4 Connection method: threaded connection, flange clamping, flange
connection, plug-in, etc. Straight pipe section requirements: Gas: The upstream straight pipe section should be ≥10DN, and the
downstream straight pipe section should be ≥5DN. Liquid: The upstream straight pipe section should be ≥20DN, and the
downstream straight pipe section should be ≥5DN. Plug-in type: the upstream straight pipe section should be ≥20DS,
and the downstream straight pipe section should be ≥7DS (DS is the measured inner diameter of
the pipeline) Display mode: (1) Remote display: pulse output, current output (with display
instrument) (2) On-site display: 8-digit LCD display cumulative flow, unit (m3) 4-digit LCD display instantaneous flow, unit (m3/h), battery power,
frequency, flow rate (3) Temperature and pressure compensation type: A. Display standard instantaneous flow and standard cumulative flow B. Display current pressure, temperature, battery voltage Output function: (1) Pulse output, p-p value is determined by the power supply (2) 4~20mA two-wire current output (3) Unit volume pulse output and sensor original pulse output (4) With RS485 communication interface Power supply: (1) DC5~24V (2) The standard 3V lithium battery is installed inside the
instrument and can be used continuously for more than eight years. (3) The temperature and pressure compensation type 3V lithium
battery can be used continuously for more than four years when installed inside the instrument.
Transmission distance: The distance from the sensor to the display instrument can reach 500m |
Features
Contact US
Xi'an Yunyi Instrument Co., Ltd
E-mail: judy@369yb.com
Phone/WhatsApp:0086 17602903009
Add.: Room B11003, 10th Floor, Sihai Center, No. 424, Taihua North
Road, Weiyang District, Xi'an 710021, Shaanxi,China