Medical Disposable Consumables PVC Cuffed and Uncuffed Endotracheal Tube with 15mm Connector
Features
- Kink-resistant
High-quality clear tube produced with soft PVC material
- Smooth Tip and Murphy eye
The tube tip is heating smooth
Murphy eye surface is heating drilling
- 15mm Connector
- Different Cuff Shape
There are 4 different cuff shapes available
- Depth Guide Mark Tube printed by high quality ink
Printing mark is not easy to be erased
We can print different mark according to requirement
Double ring and black ring available
Packaging & Delivery
-Packaging Details
-Packing: 1pc/sterilized pouch, 10pcs / inner box, Outer packing:
100pcs / shipping carton
-Delivery Time: Within 20 days. It depends on quantity of order
Product Description
standard form
Size ID (mm) | OD(mm) | Code(Cuffed) |
2.0 | 3.3 | 011-6620 |
2.5 | 3.7 | 011-6625 |
3.0 | 4.0 | 011-6630 |
3.5 | 4.7 | 011-6635 |
4.0 | 5.3 | 011-6640 |
4.5 | 6.0 | 011-6645 |
5.0 | 6.7 | 011-6650 |
5.5 | 7.3 | 011-6655 |
6.0 | 8.0 | 011-6660 |
6.5 | 8.7 | 011-6665 |
7.0 | 9.3 | 011-6670 |
7.5 | 10.0 | 011-6675 |
8.0 | 10.7 | 011-6680 |
8.5 | 11.3 | 011-6685 |
9.0 | 12.0 | 011-6690 |
9.5 | 12.7 | 011-6695 |
10.0 | 13.3 | 011-6610 |
There are 4 different cuff shapes available!!!
We can produce endotracheal tube according to customer's
requirement!!!
Instructions for use
1. Select the appropriate type of disposable endotracheal tube and
ensure that the package is intact and the sterilization of product
is within the validity period. Open the seal and take out the
disposable endotracheal tube- only the professional doctor can
operate according to the sterile procedure;
2.Test the cuff before inserting the disposable endotracheal tube:
use the syringe to inject the gas and then leak the gas. Use the
expansion rod to expand or shorten forwardly and backwardly so as
to form an adjustable angle in the front of the disposable
endotracheal tube;
3. Insert the disposable endotracheal tube according to the normal
operation method, remove the expansion rod after inserting and
finish the establishment of the airway;
4. After inserting the disposable endotracheal tube, determine the
tip position of the disposable endotracheal tube through the X-ray
visualization line; use the inflator cone to press the one-way
valve and inject the gas into the cuff. The disposable endotracheal
tube should be in safe position and avoid movement;
5. Connect the mechanical end of the suction lumen to the suction
equipment, adjust the pressure and attract the phlegm. (The suction
time should not be longer than 15s/time, and the suction action
should be gentle. The negative pressure should not exceed -6.65
kPa. The suction lumen should be washed by using 5-15 ml normal
saline after the suction of phlegm. For patient who needs to keep
the disposable endotracheal tube for a long time, the disposable
endotracheal tube should be well inserted properly into the right
depth and position and avoid the disposable endotracheal tube being
sliding out or inserting too deep.)
6. Ensure that the cuff of the disposable endotracheal tube can be
injected gas smoothly and the normal ventilation is not blocked.
Keep the airway smooth and unblocked, suck the phlegm regularly and
ensure the humidification.
7. When it is time to take the disposable endotracheal tube out,
first use the inflator cone to press the one-way valve and leak the
gas from the cuff and take the disposable endotracheal tube out. If
the gas in the cuff is too little to suck out, use the sharp
instruments to pierce the cuff, and then remove the disposable
endotracheal tube.