1.0 Mpa Zone Heating Valves 3 Wires 2 Points DN40 Water Flow Control

Brand Name:Runpaq
Certification:CE
Model Number:20P1D-T2-15-1
Minimum Order Quantity:50 pieces
Delivery Time:15-21 days
Payment Terms:L/C, T/T, D/A, D/P, Western Union
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: Room E202, No. 4528 Jiasong Road (Middle), Qingpu district 201705, Shanghai, China
Supplier`s last login times: within 7 hours
Product Details Company Profile
Product Details

3 wires 2 points control zone heating valves, hot water flow control valves 95


Product Description


Our heating zone control valves are available from DN15 to DN32, and many different thread connection ports. This CW25S zone control valve has the manual OPEN/CLOSE function in case of no electricity, lift the manual handle and turn it on or off, and it will get heat when any of the other zones call for heat. They can used for hot water flow controls, priority zoning circulators, or fan controls, central heating and cooling systems.

Features

1. Extreme long service life span ;

2. Manual Override, the valve can be operated when power failure;

3. Mini dimension and position indicator;

4. Good sealing performance, IP65 enclosure.


Application

  • HVAC system heating, ventilation, air conditioning
  • Baseboard/radiant heating
  • Convectors
  • Fan coil units
  • Underfloor heating
  • Unit ventilators
  • VAV reheat

Advantages

  • Sturday valve body with reasonable structure design, and best material to be used
No.OursNormal products
Valve shaft sealQuadruple sealsDual seals
Nut sealAuto super anaerobic glue coating, Consistent torque tighteningManual anaerobic glue, unevenly, non consistent torque tightening
Seal between valve body and housingSeal groovenone
TorqueSmoothly and lightHeavy, non consistently
DrainageYesnone


Technical data

Model20P-1.0A
Work Amp (mA)Max 80
ProtectionIP65
Power (W)<2
Operate Pressure (Mpa)PN10
Torque (NM)2
Dia rangeDN8-32 (Straight); DN15-20 (Tee, three way)
Open/close (S)Straight: < 7s; Three way: <13s
Work volt. (V)DC3-6V, DC12V
Media temp (℃)0-90
ControlCR01, CR02, CR05
Dimensions
Valve body materialConnection portDiameterDLHW
(mm)(Kg)
BrassBoth female thread full diameterDN8846310.232
DN10846310.231
DN151557380.308
DN201566380.389
DN252072470.478
3-way verticalDN151263490.31
DN201566530.367
Female-male threadDN151563380.307
DN201566380.337
DN322076500.569
Both male threadDN151568380.299


Wiring options

  • Two wires and reverse polarity (DC3-6V / DC12V)

1. Connecting SW to OPEN , the valve opens , getting the position ,automatically power off, the valve remain fully open position

2. Connection SW to CLOSE , the valve close , getting the position ,automatically power off, the valve remains side passes position(fully closed)

  • Three wires and two control points (DC3-6V / DC12V / DC24V)

1. Connecting SW to OPEN, the valve opens , getting the position ,automatically power off, the valve remain fully open position

2. Connection SW to CLOSED, the valve close , getting the position ,automatically power off, the valve remains side passes position (fully closed)

Note: AC24V/AC220V can only be used for 50K series electric valves

  • Three wires and one control point (DC3-6V/12V)

1. Connecting SW, the valve opens , getting the position ,automatically power off, thevalve remain fully open position

2. Disconnecting SW, the valve close , getting the position ,automatically power off, the valve remains side passes position (fully closed)

Note: When power is DC voltage and Red Wires is “+”,Blue wire is “—”

  • Two wires and power off return (DC3-6V/ADC9-24V/AC220V)

1. SW connecting, the valve open, getting the position and the power off automatically, the valve remains fully open/close position

2. SW disconnecting, the valve close, getting the position and power off automatically, the valve remains fully open/close position

  • Five wires micro conntroller with signal feedback (DC3-6V/12V)

1. Connecting SW and OPEN, the valve opens, getting the position green wire output the OLS signal, the controller tests the signal OLS, connect SW to STOP, the valve stops and remains fully open position

2. Connecting SW and CLOSE, the valve close, getting the position red wire output the CLS signal, the controller tests the signal CLS, connect SW to STOP, the valve stops and remains fully close position,

Note: Please make sure the signal wires "red", "black" and "green" be connected at first, then connect the power wires " yellow" and "blue".


Factory show


China 1.0 Mpa Zone Heating Valves 3 Wires 2 Points DN40 Water Flow Control supplier

1.0 Mpa Zone Heating Valves 3 Wires 2 Points DN40 Water Flow Control