

Add to Cart
275V Lightning Controller Type 1+2 Surge Protection For Power
Transfer Equipment
1-We have installed lightning rods, do we still need to use AC
surge protectors?
The current lightning protection devices include external lightning
protection and internal lightning protection. Lightning rods are
aimed at external lightning protection. This lightning protection
measure only protects against direct lightning strikes, but cannot
prevent lightning waves from invading the interior of the building.
Therefore, the building Various internal electronic components
require AC surge protectors to limit surges generated in electrical
circuits and communication lines.
2-We have not been struck by lightning in the past few decades, and
there are not many lightning activities. Do you need surge
protection?
Lightning strikes by lightning protectors are a problem of
probability. If comprehensive lightning protection is not done,
there will be hidden dangers of lightning strikes in buildings.
Once struck by lightning, it will cause casualties and equipment
damage. At the same time, lightning strikes are not the only cause
of surges in electrical circuits and communication lines. Any
electronic equipment circuit has different peak surges due to
interference from electrostatic electromagnetic induction,
high-power electrical equipment, etc. The installation of a surge
protector can effectively protect the equipment and increase the
service life of the equipment.
3-The power supply uses a fuse or MCB, do I still need an AC surge
protector?
Fuse and air switch are electrical equipment that connects and
disconnects the circuit, which mainly play the role of leakage
protection, overload protection and short-circuit protection; while
the surge protector only works when the transient overvoltage on
the line increases. To protect the circuit, it does not control the
circuit. The two need to be used together to protect the line surge
protector circuit and equipment safety.
OBV5-B60
The combination lightning current and surge arrestors OBV5-B60 meet
the type 1+2 requirement class according to IEC 61643-11. These
devices protect low-voltage consumer systems from overvoltages of
all types and are available in single-pole to four-pole versions.
The use of high-performance varistors permits a rapid response time
and a low protection level, without any line follow current. If
circumstances are uncertain and there is a risk of fire from an
overload, the internal cut-off unit disconnects the arrestor from
the mains if necessary. In addition, the QR code printed on the
arrestor allows direct access to the online installation
instructions.
Technical Parameters
Model: OBV5-B60 | |||
Maximum continuous voltage AC | Uc | V | 275/320/385/440 |
SPD to EN 61643-11 | Type 1+2 | ||
SPD to IEC 61643-1 | class I+II | ||
Lightning impulse current (10/350µs) | Iimp | kA | 12,5 |
Nominal discharge current (8/20µs) | In | kA | 30 |
Maximum discharge current (8/20µs) | Imax | kA | 60 |
Voltage protection level | Up | kV | < 1,5/1,8/2,0/2,2 |
Response time | tA | ns | < 25 |
Maximum back-up fuse | A | 125 | |
Temperature range | ϑ | ℃ | -40℃~+85℃ |
Protection rating | IP 20 | ||
Max. cable cross-section flexible (fine-wire) | mm² | 25 | |
Max. cable cross-section rigid (single wire/multi-wire) | mm² | 35 |
Feature:
1,Protect electric system and on-loading electrical apparatus from
thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC
power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715
5,It can effectively ensure the equipments work properly
Benefits
Easy installation or retrofit
Din-rail mountable
Fail-safe /self-protected designRemote indicator (optional) with
3pin NO/NC contact
IP20 finger-safe designVisual indicator
Small foot print
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Others
Technology SPD parameter(Note:According to user requirement ,can be
customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current | Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 | 275/320 | 5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Transient voltage surgesin lv power lines
Transient overvoltages are voltage surges that can reach tens
ofkilovolts with a duration of the order of microseconds.Despite
theirshort duration, the high energy content can cause serious
problemsto equipment connected to the line, from premature aging to
destruction, causing disruptions to service and financial
loss.Thistype of surge can have various different causes, including
atmospheric lightning directly striking the external
protection(lightning rods) on a building or transmission line or
the associatedinduction of electromagnetic fields on metallic
conductors.
Outdoor and longer lines are the most exposed to these fields,which
often receive high levels of induction.
It is also common for non-weather phenomena, such as transformer
centre switching or the disconnection of motors orother inductive
loads to cause voltage spikes in adjacent lines.
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so
limiting the peak voltage to an acceptablevalue for connected
electrical equipment.
A ground connection in adequate condition is, therefore,a key
aspect for effective protection against overvoltages.Monitoring
ground connection condition guaranteesproper operation of surge
protection devices.
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are
available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.