OBV5-C40-PV
Prewired modular complete unit for use in photovoltaic systems consisting of a base part and plug-in protection modules
Combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage resulting from d.c. switching arcs (patented SCI principle)
Tried and tested fault-resistant Y circuit of the OBV6-C40-PV prevents damage to the surge protective device in case of insulation faults in the generator circuit.
Integrated d.c. fuse allows safe replacement of protection modules without arc formation.
Technical Parameters
Model: OBV5-C40-PV | ||||||
Network voltage | 500Vdc | 600Vdc | 800Vdc | 900Vdc | 1000 Vdc | |
Max. operating voltage Uc | 530Vdc | 630Vdc | 840Vdc | 950Vdc | 1060 Vdc | |
Nominal discharge current ln | 20kA | |||||
Max. discharge current lmax | 40kA | |||||
Protection level (at In) Up | 1.8kV | 2.5kV | 2.8kV | 3.0kV | 3.2kV | |
Disconnector | ||||||
Thermal Disconnector | Internal | |||||
Mechanical characteristics | ||||||
Connection | by screw terminals: 4-25 mm2 | |||||
Disconnection indicator | 1 mechanical indicator by pole | |||||
Mounting | symmetrical rail 35 mm | |||||
Operating temperature | -40/+85°C | |||||
Protection class | IP20 | |||||
Standards compliance | ||||||
NF EN 61643-11 France | Parafoudre Basse Tension - Essais Classe II | |||||
IEC 61643-1 International | Low Voltage SPD - Test Class II | |||||
EN 61643-11 Europe | Parafoudre Basse Tension - Essais Classe II |
Feature&Benefits
-Easy installation or retrofit
-Din-rail mountable
-Fail-safe /self-protected designRemote indicator (optional) with
3pin NO/NC contact
-IP20 finger-safe designVisual indicator
-Small foot print
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Others
Technology SPD parameter(Note:According to user requirement ,can be
customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current | Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 | 275/320 | 5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so
limiting the peak voltage to an acceptablevalue for connected
electrical equipment.
A ground connection in adequate condition is, therefore,a key
aspect for effective protection against overvoltages.Monitoring
ground connection condition guaranteesproper operation of surge
protection devices.
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are
available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.