24/120/230VDC CCTV Surge Protection Device With Convenient Installation
CCTV Surge Protector with Power Port
CCTV surge protector is a single channel, in-line, coaxial
multi-stage video surge protector for analog cameras or head-end
applications. CCTV camera surge protector is designed to provide
multi-stage surge protection for one channel of video. The unit has
MNC type connectors at the input and output for connection to the
coax and is ideally suited for small or restricted spaces where a
single line of video needs to be protected. CCTV Surge Protector
provides power to the camera with the same unit.
Technical Parameters
Model: OBVX-3-BNC / OBVX-2-RJ45 / OBVX-2-BNC | ||||
Power | ||||
Nominal Voltage Un | 24Vdc | 120Vac | 230Vac | |
Maximum Voltage Uc | 30Vdc | 150Vac | 255Vac | |
Line Current IL | 5A | |||
Nomimal Discharge Current In (8/20µs) kA | 5kA | |||
Maximum Discharge Current Imax (8/20µs) | 10kA | |||
Protection Level Up | 0.3kV | 0.8kV | 1.2kV | |
Connection | Screw terminal : maximum 2.5 mm2 | |||
Failure Mode | Power failure and green led off | |||
Data | ||||
Maximum Voltage Uc | 8Vdc | |||
Nomimal Discharge Current In (8/20µs) kA | 5kA | |||
Maximum Discharge Current Imax (8/20µs) | 10kA | |||
Protection Level Up | 20V | |||
Connection | Screw terminal : maximum 1.5 mm2 | |||
Failure Mode | Short-circuit status (transmission fault) | |||
Video (BNC / RJ45) | ||||
Maximum Voltage Uc | 6Vdc | |||
Nomimal Discharge Current In (8/20µs) kA | 5kA | |||
Maximum Discharge Current Imax (8/20µs) | 10kA | |||
Protection Level Up | 20V | |||
Connection | BNC female coaxial connector / RJ45 | |||
Failure Mode | Short-circuit status (transmission fault) |
Feature&Benefits
1. Multi-function over-voltage protection, simple structure, less residual voltage, rapid transmission rate.
2. Applicable for combination video signal and AC power.
3. Convenient installation, maintenance simply,
Application Scope
1. Monitor video with cradle head.
2. Monitor video without cradle head.
3. Other signal equipments.
Note: The system lightning protection does not guarantee that the
equipment will not be 100% damaged by lightning; the power system
must be multi-level lightning protection;
The complete lightning protection system includes external
lightning protection and internal lightning protection. External
lightning protection refers to: lightning receptors, down
conductors, and grounding bodies, which are mainly used to defend
against direct lightning strikes. Internal lightning protection
includes: shielding, reasonable wiring, safe distance,
equipotential connection, overvoltage protection, etc., mainly used
to prevent lightning induction, ground potential counterattack,
lightning wave intrusion, etc.
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Tip: Lightning protection is probabilistic protection, and we cannot provide 100% protection.
First, lightning discharge itself has a certain degree of
randomness, and lightning parameters have certain statistical
properties, which determines that all protective measures based on
these statistical characteristics of lightning parameters cannot
provide 100% protection. Such as: direct lightning
protection-shielding characteristics; lightning current amplitude,
waveform, etc. have statistical properties;
Second, the lightning protection equipment cannot prevent the
formation of lightning flashes;
Third, lightning protection devices cannot ideally eliminate all
interference voltages/currents. The fundamental purpose of taking
protective measures is to ensure that most of the energy caused by
interference does not spread to the vulnerable parts of the device
and the staff.
Finally, the cost of protection against high-level surges with a
small probability of occurrence has risen sharply.
Others
Technology SPD parameter(Note:According to user requirement ,can be
customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current | Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 | 275/320 | 5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Importance of the ground connection
Overvoltage protectors (SPD) divert excess energy toground, so
limiting the peak voltage to an acceptablevalue for connected
electrical equipment.
A ground connection in adequate condition is, therefore,a key
aspect for effective protection against overvoltages.Monitoring
ground connection condition guaranteesproper operation of surge
protection devices.
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are
available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.