Add to Cart
CCTV Surge Protector
CCTV surge protector is a single channel, in-line, coaxial
multi-stage video surge protector for analog cameras or head-end
applications. CCTV camera surge protector is designed to provide
multi-stage surge protection for one channel of video. The unit has
MNC type connectors at the input and output for connection to the
coax and is ideally suited for small or restricted spaces where a
single line of video needs to be protected. CCTV Surge Protector
provides power to the camera with the same unit.
• OBVX3-220
Three-in-one surge arrester applicable for monitor video / audio signal / cradle head control line with voltage 220V(AC).
• OBVX2-220
Two-in-one surge arrester applicable for monitor video / audio signal with voltage 220V(AC).
• OBVX3-D24
Three-in-one surge arrester applicable for monitor video / audio signal / cradle head control line with voltage 24V(DC).
• OBVX2-D24
Two-in-one surge arrester applicable for monitor video / audio signal with voltage 24V(DC).
Technical Parameters
Model: OBVX-3-BNC / OBVX-2-RJ45 / OBVX-2-BNC | ||||
Power | ||||
Nominal Voltage Un | 24Vdc | 120Vac | 230Vac | |
Maximum Voltage Uc | 30Vdc | 150Vac | 255Vac | |
Line Current IL | 5A | |||
Nomimal Discharge Current In (8/20µs) kA | 5kA | |||
Maximum Discharge Current Imax (8/20µs) | 10kA | |||
Protection Level Up | 0.3kV | 0.8kV | 1.2kV | |
Connection | Screw terminal : maximum 2.5 mm2 | |||
Failure Mode | Power failure and green led off | |||
Data | ||||
Maximum Voltage Uc | 8Vdc | |||
Nomimal Discharge Current In (8/20µs) kA | 5kA | |||
Maximum Discharge Current Imax (8/20µs) | 10kA | |||
Protection Level Up | 20V | |||
Connection | Screw terminal : maximum 1.5 mm2 | |||
Failure Mode | Short-circuit status (transmission fault) | |||
Video (BNC / RJ45) | ||||
Maximum Voltage Uc | 6Vdc | |||
Nomimal Discharge Current In (8/20µs) kA | 5kA | |||
Maximum Discharge Current Imax (8/20µs) | 10kA | |||
Protection Level Up | 20V | |||
Connection | BNC female coaxial connector / RJ45 | |||
Failure Mode | Short-circuit status (transmission fault) |
Feature&Benefits
1. Multi-function over-voltage protection, simple structure, less residual voltage, rapid transmission rate.
2. Applicable for combination video signal and AC power.
3. Convenient installation, maintenance simply,
Application Scope
1. Monitor video with cradle head.
2. Monitor video without cradle head.
3. Other signal equipments.
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Installation and Maintenance
1. Fix the surge protective device on the wall or place the plane, connect the wire according to drawing.
2. PE connect with the earthing, Earth resistance should accord with the standard of lightning protection.
3. The distance should be within 1 meter between being protection device and surge protective device.
4. Surge protective device will damaged and signal interrupter when maximum continuous operating voltage overrun.
Note: Lightning protection is probabilistic protection, and we cannot provide 100% protection.
First, lightning discharge itself has a certain degree of
randomness, and lightning parameters have certain statistical
properties, which determines that all protective measures based on
these statistical characteristics of lightning parameters cannot
provide 100% protection. Such as: direct lightning
protection-shielding characteristics; lightning current amplitude,
waveform, etc. have statistical properties;
Second, the lightning protection equipment cannot prevent the
formation of lightning flashes;
Third, lightning protection devices cannot ideally eliminate all
interference voltages/currents. The fundamental purpose of taking
protective measures is to ensure that most of the energy caused by
interference does not spread to the vulnerable parts of the device
and the staff.
Finally, the cost of protection against high-level surges with a
small probability of occurrence has risen sharply.
Others
Technology SPD parameter(Note:According to user requirement ,can be
customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current | Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 | 275/320 | 5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Tip: How can I distinguish the quality of the lightning arrester?
1. It can be seen from the reaction time: determine whether the
lightning arrester can respond in time and quickly discharge the
lightning current.
2. It can be seen from the insertion loss: this refers to the
installation of a lightning protector, the impact of this lightning
protector on the line, the smaller the better
3. It can be seen from the number of impact resistance: determines
the service life of the lightning arrester. Generally, the gas
discharge tube will not drop after being placed for a period of
time. If you want to check its quality, you can use an adjustable
high-voltage DC power supply to test .
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are
available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?