Thermal Abuse Test Chamber for Battery Cell
1. IEC 62133-2017
2. UL 1642
3. GB 31241-2014
Model | BE-8103 |
---|---|
Structure | All-in-one structure, the door uses explosion-proof lock + explosion-proof chain |
Normal temperature to 150°C (Adjustable) | |
Temperature Range | |
Controlling Accuracy | ±0.5℃ |
Temperature Deviation | ±2.0℃, No load |
Heating Rate | RT~150°C (Linear 5°C/min) |
Control Display | PLC touch type (7 inch) + remote control |
Working Cabinet Dimension | W600XD500XH600 mm |
External Dimension | W940XD780XH1620 mm |
Inner Chamber Material | SUS304 Stainless steel with mirror-finish |
External Chamber Material | SECC steel plate, fine powder paint coating (thickness 1.5mm) |
Bottom | With universal wheel |
Observation Window | 390 X 360mm (20mm thick explosion-proof glass, explosion-proof mesh) |
Insulation Material | Imported high-density glass wool, good heat insulation, to ensure maximum temperature insulation, tight sealing materials for high temperature resistant silicone, withstanding high temperatures over 300 degrees for a long time |
Terminal Hole | Diameter 50mm Terminal hole on the left and right sides |
Power Supply | 220V / 50HZ / 4.0KW |
USB Interface | With USB interface, the test data can be exported |
Auxiliary Function | Explosion-proof pressure relief device, smoke exhaust device, explosion-proof lighting device, electronic door lock system, safety stop switch |
A: Relevant standard test requirements
Single battery safety test
The heating test is carried out as follows:
1. The single battery is charged according to the method of 6.1.3
2. Put the single battery into the temperature chamber.
3. For lithium-ion batteries, the temperature chamber is increased from room temperature to 130 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining the temperature for 30 minutes.
4. For nickel metal cyanide batteries, the temperature chamber is raised from room temperature to 85 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.
5. Observe for 1h.
B: Battery module safety test
1. The battery module battery shall be charged according to the method in 6.1.4.
2. For lithium-ion batteries, the temperature chamber is raised from room temperature to 130 ° C ± 2 ° C at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 30 minutes.
3. For nickel metal cyanide batteries, the temperature chamber is raised to 85 ° C ± 2 ° C at room temperature at a rate of 5 ° C / min, and the heating is stopped after maintaining this temperature for 2h.
4. Observe for 1h.