Add to Cart
220v 1.5kw Variable Frequency Drives Contain Vector Control Model
Contain Vector Control Model Apply For Industrial Motor Control Single Phase 220v 1.5kw Inverter
Product Description
The SVD-P is a general-purpose, high performance variable speed applications, offers a series of powerful features, idea for demanding application , compact, high efficiency
equipped with high start torque, overload capability,fast dynamic,built-in PID, PLC, offering a high precise motor control make of speed DSP, high margin IGBT Module, conformal coating, robust time-proven design
Features
SFVC/CLVC/VF
High Start Torque
Fast Dynamic
High Frequency & Torque stability
Flexible
Cost-effective
Item | Specification | |
Standard functions | Max O/P frequency | • Vector control: 0–300 Hz • V/F control: 0–320 Hz |
Carrier frequency | 0.5–16 kHz automatically adjusted according to the load features. | |
I/P Freq. resolution | Digital setting: 0.01 Hz, Analog setting: maximum frequency x 0.025% | |
Control mode | • Sensorless flux vector(SFVC) • Closed-loop vector(CLVC) • V/F | |
Startup torque | • G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC) • P type: 0.5 Hz/100% | |
Speed range | 1:100 (SFVC) 1:1000 (CLVC) | |
Speed stability | • ± 0.5% (SFVC) • ± 0.02% (CLVC) | |
Torque accuracy | ± 5% (CLVC) | |
Overload capacity | • G type: 60s for 150%, 3s for 180% • P type: 60s for 120%, 3s for 150% | |
Torque boost | • Fixed boost • Customized boost 0.1%–30.0% | |
V/F curve | • Straight-line V/F curve • Multi-point V/F curve • N-power V/F curve | |
Ramp mode | • Straight-line • S-curve • 4 groups of ac/decceleration time 0.0–6500.0s | |
DC braking | •frequency: 0.00 Hz to Max Freq • Time: 0.0–36.0s | |
JOG control | Frequency: 0.00–50.00 Hz acceleration/deceleration time: 0.0–6500.0s | |
Voltage regulation | Maintain output voltage against the input mains voltage fluctuation. | |
Stall control | Smart current and voltage regulation to avoid tripping OCP/OVP | |
Torque limit | Smart Torque regulation to avoid tripping OCP | |
Enhanced functions | High performance | High-performance current vector control technology. |
Power dip ride through | Manage speed of motor to ride through short period power interruption | |
Rapid current limit | It helps to avoid frequent overcurrent faults of the AC drive. | |
Virtual I/Os | Five groups of virtual DI/Dos can realize simple logic control. | |
Timing control | Time range: 0.0–6500.0 minutes | |
Multi-motor switchover | 4 motors with individual motor parameters. | |
Multi-communication | Modbus-RTU, PROFIBUS DP, CANopen. | |
Motor overheat protect | Accept the motor temperature sensor input for overheat protection. | |
Encoder types | supports: differential, open-collector ,resolver, UVW and SIN encoder | |
RUN | Command source | • Operation panel • Control terminals • Serial communication port |
Frequency source | Up to 10 sources | |
Input terminal | • 5 x DI (1 high-speed pulse) • 2 x AI (0–10 V/ or 4–20 mA) | |
• Extension : 5 x DI , 1 AI | ||
Output terminal | • 2 DO (1 high-speed pulse) • 1 relay • 1 AO 0–20 mA or 0–10 V Extension: 1 DO, 1 relay output, 1 AO 0–20 mA or 0–10 V | |
Panel | Display | LED numeric displays with LED indicator |
Environment | operation temperature | .-10°C to 50°C derating needed between 40~50°C |
Humidity | 0~ 97%RH, non condensing | |
IP level | IP20 |
Housing types for different voltage and power classes
Voltage & Power Class | Housing Type |
Single-phase 220 V | |
0.4–2.2 kW | Plastic housing |
Three-phase 220 V | |
0.4–7.5 kW | Plastic housing |
11–75 kW | Sheet metal housing |
Three-phase 380 V | |
0.75–15 kW | Plastic housing |
18.5–400 kW | Sheet metal housing |
Three-phase 480 V | |
0.75–15 kW | Plastic housing |
18.5–400 kW | Sheet metal housing |
Three-phase 690 V | |
55–500 kW | 55–500 kW |