OOM102-1 OOM102 OOM202 OOM201 Envitec Oxygen Cell Sensor

Brand Name:Envitec
Certification:CE
Model Number:OOM102-1 OOM202 OOM201
Minimum Order Quantity:1pcs
Delivery Time:3-5 working days
Payment Terms:full before shipment
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

OOM102-1 OOM102 OOM202 OOM201 Envitec Oxygen Cell Sensor 100% Genuine New


The EnviteC medical oxygen sensor is designed to be used as the oxygen sensor component of the oxygen analyzer to measure the oxygen concentration in the following breathing gas mixture

application:

Sensing device for oxygen in

• Oxygen concentrator control device

• Medical ventilator

• Anesthesia equipment

• Incubator.

Use is limited to system monitoring. The sensor is not suitable for breath analysis of breathing gas. Please refer to

To the instructions for use! If the sensor is going to be replaced

The original oxygen sensing component of the oxygen analyzer,

Please refer to the EnviteC XRL cross-reference list to select

The right sensor


Technical Specifications OOM202


Model NumberOOM202
Nominal Sensor Lifetime250000 Percent Volume Oxygen Hours
Electrical InterfaceGold Plated Slip Rings
Output Signal in Air170A - 230A No Temperature Compensation
Response Time T 90%Less Than 12 Seconds
WeightApprox. 28 Grams
UsageHospital

Technical Specifications OOM102-1 OOM102


Model / Part NumberOOM102-1
Target gasesOXYGEN
Measuring Range0-100%
Operating Voltage5V
Oxygen Pressure Range2 bar

Technical Specifications OOM201


Measurement range0 % ... 100 % oxygen (at atmosPHiliphhiliperic pressure)
Nominal sensor lifetime≥ 500 000 % volume oxygen hours
Output in ambient air14 mV ... 20.7 mV (Dual Cathode), load 600 Ohms
Electrical interfaceGold plated slip rings
Accuracymeets ISO 80601-2-55 requirements
Repeatability< 1 % volume O2 at constant temperature and pressure
Linearity error< 3 % relative
Response time< 12 s to 90 % of final value
Zero offset voltage< 200 µV in 100 % nitrogen, applied for 5 min
Cross interferencemeets ISO 80601-2-55 requirements
Influence of humidity-0.03 % rel. per % RH at 25 °C
Pressure range0.6 bar ... 2 bar (ppO2 0 ... 1250 mbar O2 )
Influence of pressureproportional to change in oxygen partial pressure
Influence of mechanical shock< 1 % relative after a fall from 1 m
Operating temperature0 °C ... +50 °C
Temperature compensationno temperature compensation
Operating humidity0 % ... 99 % RH non-condensing
Long term output drift< 1 % volume oxygen per month typically < -15 % relative over lifetime
Storage temperature-20 °C ... +50 °C
Recommended storage+5 °C … +15 °C
Recommended load≥ 10 kOhms
Warm-up time< 30 minutes, after replacement of sensor
Weightapproximately 28 grams
Part number01-00-0014

Mechanical drawing (All dimension in mm)