3C5A Mindray Ultrasound Convex Array Probe For DC-N3 DC-3 DC-6 Ultrasound Machine

Brand Name:Mindray
Model Number:3C5A
Minimum Order Quantity:1pcs
Delivery Time:3-5 working days
Payment Terms:T/T(wire transfer), Western Union, Paypal
Packaging Details:Carton
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: TianHe District,GuangZhou,GuangDong
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

3C5A Mindray Ultrasound Convex Array Probe For DC-N3 DC-3 DC-6 Ultrasound Machine


The frequency bandwidth of Mindray 3C5a convex ultrasonic transducer is 2.5/3.5/5.0/H4.6/H6.0 MHz. The 3C5s probe is suitable for adult abdominal, obstetrics, vascular and pediatric abdominal imaging applications. This probe is compatible with the Mindray DC-N3 console ultrasound machine.


Specification


Product Name

Mindray 3C5A Ultrasound Convex Array Probe for DC-N3 DC-3 DC-6 ultrasound machine


BrandMindray
Part No.3C5A
Type

Convex Array


frequency bandwidth2.5/3.5/5.0/H4.6/H6.0 MHz
Applicationsadult abdomen, OB/GYN, vascular and pediatric abdominal imaging applications
Compatible for

DC-N3 DC-3 DC-6 ultrasound machine



The sensor is classified as "IPX7" according to the degree of protection against harmful ingress of water (from the sensor head to the cable protector).

The connectors are not waterproof and must not be immersed in liquids such as disinfectants.

The transducer is as shown below



No.NameFunction
<1>Transducer headConverts electrical signals into ultrasonic and focuses the sound beam in a certain direction; At the same time, it receives reflected ultrasonic signals, converts them into electrical signals and transmits them through cables. The lens on the surface is an acoustic lens. Apply ultrasonic gel to the acoustic lens for it to work properly.
<2>Needle-guided bracket fix tabs and groovesProvides mounting support of the needle-guided bracket.
<3>Transducer cableTransmits electrical signals between the transducer body and connector
<4>Transducer connectorConnects the transducer and cable to the ultrasonic diagnostic system.
<5>Lock handleLocks the connector to the ultrasonic diagnostic system.

Tips: The transducers’ structure marked in the figure above may vary with the matched needle-guided brackets.


Connecting and Disconnecting the Transducer

For non-portable Doppler Ultrasound System Compliant Transducer

Connect the converter:

After freezing or shutting down the ultrasound system, align the connector with the ultrasound system's transducer port and rotate the locking handle 90° clockwise to lock securely. See below:

Disconnect the sensor:

After the system freezes or shuts down, rotate the locking handle 90° counterclockwise to unlock the transducer. Pull the connector straight out to remove it.

See below:


For Portable Doppler Ultrasound System Compliant Transducer

Connect the converter:

To connect the transducer, push the plug into the socket until it stops. Move the transducer lock lever, located next to the jack, to the up position. See below.

Disconnect the sensor:

To disconnect the transducer, move the transducer locking lever to the down position and pull the transducer steadily out of the socket. See below.



If you're interested in 3C5A Mindray Ultrasound Convex Array Probe For DC-N3 DC-3 DC-6 Ultrasound Machine ,feel free to contact us .Thank you .


China 3C5A Mindray Ultrasound Convex Array Probe For DC-N3 DC-3 DC-6 Ultrasound Machine supplier

3C5A Mindray Ultrasound Convex Array Probe For DC-N3 DC-3 DC-6 Ultrasound Machine